NEC UN552S External Controls - Page 20
Get Timing Report and Timing reply.
View all NEC UN552S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
5.5.2 Get Timing Report and Timing reply. The controller requests the monitor to report the displayed image timing. Command code STX ETX '0' '7' Send "07"(30h, 37h) as Get Timing Report command. Complete "Get Timing Report" command packet as follows; ASCII: 01h-30h-41h-30h-41h-30h-34h-02h-30h-37h-03h-CHK-0Dh SOH-'0'-'A'-'0'-'A'-'0'-'4'-STX-'0'-'7'-ETX-CHK- CR The monitor replies status as the following format; STX Command SS H Freq. V Freq. ETX '4' 'E' Hi Lo MSB LSB MSB LSB SS: Timing status byte Bit 7 = 1: Sync Frequency is out of range. Bit 6 = 1: Unstable count Bit 5-2 Reserved (Don't care) Bit 1 1:Positive Horizontal sync polarity 0:Negative Horizontal sync polarity. Bit 0 1:Positive Vertical sync polarity. 0:Negative Vertical sync polarity. H Freq: Horizontal Frequency in unit 0.01kHz V Freq: Vertical Frequency in unit 0.01Hz Ex.) When H Freq is '1''2''A''9' (31h, 32h, 41h, 39h), it means 47.77kHz. (20/145)