NEC UN552S External Controls - Page 139
Data0-Data12: Log Data of Proof of Play of STOP 26byte : Same
View all NEC UN552S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 139 highlights
Header SOH (01h) : Start of Header '0' (30h) : Reserved Monitor ID: Specify the Monitor ID from which you want to get status. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h) : Message sender is the controller. 'A' (41h) : Message Type is "Command". '3'-'4' (33h, 36h) : Message length is 38 bytes. Message STX (02h): Start of Message 'C'-'B'-'1'-'5': Proof of Play reply command '0'-'3' (30h,33h): Get Proof of Play Number to Number log command LNR (H): log number being returned (High byte) LNR (L): log number being returned (Low byte) Data(0)-Data(12): Log Data of Proof of Play of STOP (26byte) : Same as "Get Proof of Play Current" * Refer to "Get Proof of Play Current" ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet (139/145)