NEC X981UHD External Control Codes - Page 105

Auto Power Save Time Write

Page 105 highlights

19.4 Auto Power Save Time Write This command is used in order to write the setting of Auto Power Save Time. 1) The controller requests the monitor to write Time. Header SOH-'0'-Monitor ID'0'-'A'-'0'-'A' Message STX-'C'-'A'-'0'-'B'-0'-'3'-TIME-ETX Check code BCC Delimiter CR Header SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type is "Command". '0'-'A'(30h,41h): Message length (10byte) Message STX (02h): Start of Message 'C'-'A'-'0'-'B' (43h, 41h, 30h, 42h): Power Save Mode command '0'-'3' (30h, 33h): Auto Power Save Time Write TIME: AUTO POWER SAVE TIME (sec.) 00h (30h, 30h) - 78h (37h, 38h): 1 (5dec.) - 120 (600sec.) ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet 2) The monitor replies a written in result. Header Message SOH-'0'-'0'-Monitor ID- STX-'C'-'B'-'0'-'B'-'0'-'3'-ST-ETX 'B'-'0'-'8' Check code Delimiter BCC CR Header SOH (01h): Start of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller. Monitor ID: Indicate a replying Monitor ID. Ex.) When this byte is set to 'A', replying monitor's ID is '1'. 'B' (42h): Message type is "Command reply". '0'-'8'(30h,38h): Message length (8byte) Message STX (02h): Start of Message 'C'-'B'-'0'-'B' (43h, 42h, 30h, 42h): Power Save Mode Reply '0'-'3' (30h, 33h): Auto Power Save Time Write ST: Error Status No Error : 00h (30h, 30h) Error : 01h (30h, 31h) ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 "Check code" for a BCC calculation. (105/130)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

(105/130)
19.4 Auto Power Save Time Write
This command is used in order to write the setting of Auto Power Save Time.
1) The controller requests the monitor to write Time.
Header
Message
Check code
Delimiter
SOH-'0'-Monitor ID-
'0'-'A'-'0'-'A'
STX-'C'-'A'-'0'-'B'-0'-'3'-TIME-ETX
BCC
CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'A'(30h,41h): Message length (10byte)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'B' (43h, 41h, 30h, 42h): Power Save Mode command
'0'-'3' (30h, 33h): Auto Power Save Time Write
TIME: AUTO POWER SAVE TIME (sec.)
00h (30h, 30h) – 78h (37h, 38h): 1 (5dec.) – 120 (600sec.)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a written in result.
Header
Message
Check code
Delimiter
SOH-'0'-'0'-Monitor ID-
'B'-'0'-'8'
STX-'C'-'B'-'0'-'B'-'0'-'3'-ST-ETX
BCC
CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.
'B' (42h): Message type is "Command reply".
'0'-'8'(30h,38h): Message length (8byte)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'B' (43h, 42h, 30h, 42h): Power Save Mode Reply
'0'-'3' (30h, 33h): Auto Power Save Time Write
ST: Error Status
No Error : 00h (30h, 30h)
Error
: 01h (30h, 31h)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.