NEC X981UHD External Control Codes - Page 62
INPUT: Timer input
View all NEC X981UHD manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
ON_MIN: Turn on time (minute) '0'-'0'(30h, 30h): 0 | '3'-'B'(33h, 42h): 59 '3'-'C'(33h, 43h): On timer isn't set. OFF_HOUR: Turn off time (hour) '0'-'0'(30h, 30h): 00 | '1'-'7'(31h, 37h): 23 (=17h) '1'-'8'(31h, 38h): Off timer isn't set. OFF_MIN: Turn off time (minute) '0'-'0'(30h, 30h): 0 | '3'-'B'(33h, 42h): 59 (=3Bh) '3'-'C'(33h, 43h): Off timer isn't set. INPUT: Timer input '0'-'0'(30h, 30h): DVI1 '0'-'7'(30h,30h): No mean (Works on last memory) WD: Week setting bit 0: MONDAY bit 1: TUESDAY bit 2: WEDNESDAY bit 3: THURSDAY bit 4: FRIDAY bit 5: SATURDAY bit 6: SUNDAY EX. '0'-'1'(30h, 31h): MONDAY '0'-'4'(30h, 34h): TUESDAY '0'-'F'(30h, 46h): MONDAY, TUESDAY, WEDNESDAY and THURSDAY '7'-'F'(37h, 46h): MONDAY to SUNDAY FL: Option bit 0: 0:once 1:Everyday bit 1: 0:once 1:Every week bit 2: 0:Disable 1:Enable EX. '0'-'1'(30h, 31h): Disable, Everyday '0'-'4'(30h, 34h): Enable, once ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet (62/130)