NEC X981UHD External Control Codes - Page 18

Set parameter

Page 18 highlights

5.3 Set parameter STX OP code OP code Set Value ETX page Hi Lo Hi Lo MSB LSB 1st 2nd-3rd 4th-5th 6th-9th 10th Send this message to change monitor's adjustment and so on. The controller requests a monitor to change value. 1stbyte) STX: Start of Message ASCII STX (02h) 2nd-3rdbytes) OP code page: Operation code page This OP code page data must be encoded to ASCII characters. Ex.) The byte data 02h must be encoded to ASCII '0' and '2' (30h and 32h). Refer to the Operation code table. 4th-5thbytes) OP code: Operation code This OP code data must be encoded to ASCII characters. Ex.) OP code 1Ah -> OP code (Hi) = ASCII '1' (31h) OP code (Lo) = ASCII 'A' (41h) Refer to the Operation code table. 6th-9thbytes) Set value: (16bit) This data must be encoded to ASCII characters. Ex.) 0123h -> 1st(MSB) = ASCII '0' (30h) 2nd = ASCII '1' (31h) 3rd = ASCII '2' (32h) 4th(LSB) = ASCII '3' (33h) 10thbyte) ETX: End of Message ASCII ETX (03h) (18/130)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

(18/130)
5.3 Set parameter
Send this message to change monitor’s adjustment and so on.
The controller requests a monitor to change value.
1
st
byte) STX: Start of Message
ASCII STX (02h)
2
nd
-3
rd
bytes) OP code page: Operation code page
This OP code page data must be encoded to ASCII characters.
Ex.) The byte data 02h must be encoded to ASCII '0' and '2' (30h and 32h).
Refer to the Operation code table.
4
th
-5
th
bytes) OP code: Operation code
This OP code data must be encoded to ASCII characters.
Ex.) OP code 1Ah ->
OP code (Hi) = ASCII '1' (31h)
OP code (Lo) = ASCII 'A' (41h)
Refer to the Operation code table.
6
th
-9
th
bytes) Set value: (16bit)
This data must be encoded to ASCII characters.
Ex.) 0123h ->
1
st
(MSB) = ASCII '0' (30h)
2
nd
= ASCII '1' (31h)
3
rd
= ASCII '2' (32h)
4
th
(LSB)
= ASCII '3' (33h)
10
th
byte) ETX: End of Message
ASCII ETX (03h)
STX
OP code
page
OP code
Set Value
ETX
Hi
Lo
Hi
Lo
MSB
LSB
1
st
2
nd
-3
rd
4
th
-5
th
6
th
-9
th
10
th