NEC X981UHD External Control Codes - Page 70

Pg-on Hours-on Min-off Hours-off Min-input-wd-fl: Schedule Data

Page 70 highlights

EX. '0'-'1'(30h, 31h): MONDAY '0'-'4'(30h, 34h): TUESDAY '0'-'F'(30h, 46h): MONDAY, TUESDAY, WEDNESDAY and THURSDAY '7'-'F'(37h, 46h): MONDAY to SUNDAY FL: Option bit 0: 0:once 1:Everyday bit 1: 0:once 1:Every week bit 2: 0:Disable 1:Enable * When bit 0 and bit 1 are '1', it behaves as Everyday. EX. '0'-'1'(30h, 31h): Disable, Everyday '0'-'4'(30h, 34h): Enable, once ETX (03h): End of Message Check code BCC: Block Check Code Refer to the section 4.3 "Check code" for a BCC calculation. Delimiter CR (0Dh): End of packet 2) The monitor replies a data for confirmation. Header Message SOH-'0'-'0'-Monitor ID'B'-'1'-'8' STX-'C'-'3'-'1'-'4'-ST-PG-ON HOUR-ON MINOFF HOUR-OFF MIN-INPUT-WD-FL-ETX Check code BCC Header SOH (01h): Start of Header '0' (30h): Reserved '0' (30h): Message receiver is the controller. Monitor ID: Indicate a replying Monitor ID. Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command reply". '1'-'8'(31h, 38h): Message length Message STX (02h): Start of Message 'C'-'3'-'1'-'4' (43h, 33h, 31h, 34h): Schedule writes reply command ST: Schedule Status command '0'-'0'(30h, 30h): No error '0'-'1'(30h, 31h): Error PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL: Schedule data PG: Program No. '0'-'0'(30h, 30h): Program No.1 | '0'-'6'(30h, 36h): Program No.7 ON_HOUR: Turn on time (hour) '0'-'0'(30h, 30h): 00 | '1'-'7'(31h, 37h): 23 (=17h) '1'-'8'(31h, 38h): ON timer isn't set. ON_MIN: Turn on time (minute) '0'-'0'(30h, 30h): 0 | '3'-'B'(33h, 42h): 59 '3'-'C'(33h, 43h): On timer isn't set. OFF_HOUR: Turn off time (hour) '0'-'0'(30h, 30h): 00 | Delimiter CR (70/130)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

(70/130)
EX.
'0'-'1'(30h, 31h): MONDAY
'0'-'4'(30h, 34h): TUESDAY
'0'-'F'(30h, 46h): MONDAY, TUESDAY, WEDNESDAY and THURSDAY
'7'-'F'(37h, 46h): MONDAY to SUNDAY
FL: Option
bit 0: 0:once 1:Everyday
bit 1: 0:once 1:Every week
bit 2: 0:Disable 1:Enable
* When bit 0 and bit 1 are '1', it behaves as Everyday.
EX.
'0'-'1'(30h, 31h): Disable, Everyday
'0'-'4'(30h, 34h): Enable, once
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a data for confirmation.
Header
Message
Check
code
Delimiter
SOH-'0'-'0'-Monitor ID-
'B'-'1'-'8'
STX-'C'-'3'-'1'-'4'-ST-PG-ON HOUR-ON MIN-
OFF HOUR-OFF MIN-INPUT-WD-FL-ETX
BCC
CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'1'-'8'(31h, 38h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'1'-'4' (43h, 33h, 31h, 34h): Schedule writes reply command
ST: Schedule Status command
'0'-'0'(30h, 30h): No error
'0'-'1'(30h, 31h): Error
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): ON timer isn't set.
ON_MIN:
Turn on time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
'3'-'C'(33h, 43h): On timer isn’t set.
OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
|