Netgear FS518T FS518 Installation Guide - Page 45

Fiber Optic Cables, Fiber Cable Specifications, Gigabit Cable Guidelines

Page 45 highlights

Fiber Optic Cables Installation Guide for the Model FS518 Fast Ethernet Switch In North America, use EIA-569-A horizontal 62.5/125 µm multimode optical fiber cable (ANSI/EIA/TIA-492AAAA). Internationally, use ISO/IEC 11801 62.5/125 µm multimode optical fiber cable (IEC 793-2 type A1b, with 1.0 db/km attenuation and 500 MHz/km bandwidth). Refer to Table C-2 for the minimum requirements of fiber optic cable. Fiber Cable Specifications Table C-2 lists the electrical requirements of fiber cable. Table C-2. Electrical Requirements of Fiber Optic Cable Specification Number of strands Cable type Numerical aperture Total link budget Modal band Zero dispersion wavelength Dispersion slope Fiber Optic Cable Two 62.5/125 µm multimode fiber optic cable 0.275 11 db 500 MHz/km 1295 to 1365 nm < 0.093 ps/nm2-km Gigabit Cable Guidelines Table C-3 lists the distance limitations for Gigabit fiber connections. Table C-3. Gigabit Cable Guidelines Multimode Fiber Operating Range 62.5/125 Micron 2 to 260 meters 50/125 Micron 2 to 525 meters Cabling Guidelines C-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

Installation Guide for the Model FS518 Fast Ethernet Switch
Cabling Guidelines
C-5
Fiber Optic Cables
In North America, use EIA-569-A horizontal 62.5/125
µ
m multimode optical fiber cable
(ANSI/EIA/TIA-492AAAA).
Internationally, use ISO/IEC 11801 62.5/125
µ
m multimode optical fiber cable (IEC 793-2 type
A1b, with 1.0 db/km attenuation and 500 MHz/km bandwidth). Refer to
T
able
C-
2
for the
minimum requirements of fiber optic cable.
Fiber Cable Specifications
T
able
C-
2
lists the electrical requirements of fiber cable.
Gigabit Cable Guidelines
Table C-3 lists the distance limitations for Gigabit fiber connections.
Table C-2.
Electrical Requirements of Fiber Optic Cable
Specification
Fiber Optic Cable
Number of strands
Two
Cable type
62.5/125
µ
m
multimode fiber optic cable
Numerical aperture
0.275
Total link budget
11 db
Modal band
500 MHz/km
Zero dispersion wavelength
1295 to 1365 nm
Dispersion slope
< 0.093 ps/nm
2
-km
Table C-3.
Gigabit Cable Guidelines
Multimode Fiber
62.5/125 Micron
50/125 Micron
Operating Range
2 to 260 meters
2 to 525 meters