Onkyo SC886 Instruction Manual - Page 120
Using the 12V Triggers, Hookup, Zone2, Main/Zone2, Zone2/Zone3, Main/Zone2/Zone3
UPC - 751398008405
View all Onkyo SC886 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 120 highlights
Zone 2 and Zone 3-Continued Using the 12V Triggers 3 The 12V triggers A, B, and C can be used to turn on 12V trigger-capable components automatically when they are selected as the input source. The triggers can be set so that they activate when a connected component is selected as the input source for the main room, Zone 2, Zone 3, or any combination of rooms. When triggered, the output from a 12V TRIGGER OUT goes high (+12 volts, 100 milliamperes max). 4 Hookup • Use a miniplug cable to connect the AV controller's 12V TRIGGER OUT A, B, or C jack to the 12 V trig- ger input on a connected component. When several components are turned on simultaneously by using triggers A, B, and C, depending on the type of components, a large amount of current may be drawn momentarily. To prevent this, you can delay trigger sig- 5 nals A, B, and C individually. Another application for trigger delay is eliminating the "thump" noise that's sometimes heard when a source component is turned on. Delaying the trigger signal for your power amplifier so that it's the last component to be turned on will accom- plish this. 1 Press the [RECEIVER] REMOTE MODE button, followed by the [SETUP] button. The main menu appears onscreen. 2 120 Use the Up and Down [R]/[X] buttons to select "6. Miscellaneous," and then press [ENTER]. The Miscellaneous menu appears. 6. Miscellaneous 1. Volume Setup 2. OSD Setup 3. Trigger A Setup 4. Trigger B Setup 6 5. Trigger C Setup MOVE ENTER ENTER RETURN RETURN SETUP EXIT Use the Up and Down [R]/[X] buttons to select "12V Trigger A, B, or C," and then press [ENTER]. The 12V Trigger A/B/C Setup screen appears. 6-3. 12V Trigger A Setup Delay 0sec DVD Main VCR/DVR Main CBL/SAT Main GAME/TV Main AUX1 Main AUX2 Main TAPE Main TUNER Main CD Main MOVE VALUE RETURN RETURN SETUP EXIT Use the Up and Down [R]/[X] buttons to select "Delay," and use the Left and Right [F]/[S] buttons to select: 0 sec, 1 sec, 2 sec, or 3 sec. When 0 sec is selected, the trigger signal is output as soon as the input source is changed. Use the Up and Down [R]/[X] buttons to select an input source, and use the Left and Right [F]/[S] buttons to select an option. Off: No trigger signal is output. A 12-volt trigger signal is output when the connected component is selected as the source for: Main: Main room. Zone2: Zone 2. Main/Zone2: Main room or Zone 2. Zone3: Zone 3. Main/Zone3: Main room or Zone 3. Zone2/Zone3: Zone 2 or Zone 3. Main/Zone2/Zone3: Main room, Zone 2, or Zone 3. When you've finished, press the [SETUP] button. Setup closes.