Onkyo SC886 Instruction Manual - Page 120

Using the 12V Triggers, Hookup, Zone2, Main/Zone2, Zone2/Zone3, Main/Zone2/Zone3

Page 120 highlights

Zone 2 and Zone 3-Continued Using the 12V Triggers 3 The 12V triggers A, B, and C can be used to turn on 12V trigger-capable components automatically when they are selected as the input source. The triggers can be set so that they activate when a connected component is selected as the input source for the main room, Zone 2, Zone 3, or any combination of rooms. When triggered, the output from a 12V TRIGGER OUT goes high (+12 volts, 100 milliamperes max). 4 Hookup • Use a miniplug cable to connect the AV controller's 12V TRIGGER OUT A, B, or C jack to the 12 V trig- ger input on a connected component. When several components are turned on simultaneously by using triggers A, B, and C, depending on the type of components, a large amount of current may be drawn momentarily. To prevent this, you can delay trigger sig- 5 nals A, B, and C individually. Another application for trigger delay is eliminating the "thump" noise that's sometimes heard when a source component is turned on. Delaying the trigger signal for your power amplifier so that it's the last component to be turned on will accom- plish this. 1 Press the [RECEIVER] REMOTE MODE button, followed by the [SETUP] button. The main menu appears onscreen. 2 120 Use the Up and Down [R]/[X] buttons to select "6. Miscellaneous," and then press [ENTER]. The Miscellaneous menu appears. 6. Miscellaneous 1. Volume Setup 2. OSD Setup 3. Trigger A Setup 4. Trigger B Setup 6 5. Trigger C Setup MOVE ENTER ENTER RETURN RETURN SETUP EXIT Use the Up and Down [R]/[X] buttons to select "12V Trigger A, B, or C," and then press [ENTER]. The 12V Trigger A/B/C Setup screen appears. 6-3. 12V Trigger A Setup Delay 0sec DVD Main VCR/DVR Main CBL/SAT Main GAME/TV Main AUX1 Main AUX2 Main TAPE Main TUNER Main CD Main MOVE VALUE RETURN RETURN SETUP EXIT Use the Up and Down [R]/[X] buttons to select "Delay," and use the Left and Right [F]/[S] buttons to select: 0 sec, 1 sec, 2 sec, or 3 sec. When 0 sec is selected, the trigger signal is output as soon as the input source is changed. Use the Up and Down [R]/[X] buttons to select an input source, and use the Left and Right [F]/[S] buttons to select an option. Off: No trigger signal is output. A 12-volt trigger signal is output when the connected component is selected as the source for: Main: Main room. Zone2: Zone 2. Main/Zone2: Main room or Zone 2. Zone3: Zone 3. Main/Zone3: Main room or Zone 3. Zone2/Zone3: Zone 2 or Zone 3. Main/Zone2/Zone3: Main room, Zone 2, or Zone 3. When you've finished, press the [SETUP] button. Setup closes.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

120
Zone 2 and Zone 3
—Continued
The 12V triggers A, B, and C can be used to turn on 12V
trigger-capable components automatically when they are
selected as the input source. The triggers can be set so
that they activate when a connected component is
selected as the input source for the main room, Zone 2,
Zone 3, or any combination of rooms.
When triggered, the output from a 12V TRIGGER OUT
goes high (+12 volts, 100 milliamperes max).
Hookup
Use a miniplug cable to connect the AV controller’s
12V TRIGGER OUT A, B, or C jack to the 12 V trig-
ger input on a connected component.
When several components are turned on simultaneously
by using triggers A, B, and C, depending on the type of
components, a large amount of current may be drawn
momentarily. To prevent this, you can delay trigger sig-
nals A, B, and C individually. Another application for
trigger delay is eliminating the “thump” noise that’s
sometimes heard when a source component is turned on.
Delaying the trigger signal for your power amplifier so
that it’s the last component to be turned on will accom-
plish this.
Using the 12V Triggers
1
Press the [RECEIVER] REMOTE
MODE button, followed by the
[SETUP] button.
The main menu appears onscreen.
2
Use the Up and Down [
q
]/[
w
] but-
tons to select “6. Miscellaneous,”
and then press [ENTER].
The Miscellaneous menu appears.
6. Miscellaneous
1. Volume Setup
2. OSD Setup
3. Trigger A Setup
4. Trigger B Setup
5. Trigger C Setup
MOVE
ENTER
RETURN
ENTER
RETURN
EXIT
SETUP
3
Use the Up and Down [
q
]/[
w
] but-
tons to select “12V Trigger A, B,
or C,” and then press [ENTER].
The 12V Trigger A/B/C Setup screen
appears.
4
Use the Up and Down [
q
]/[
w
] but-
tons to select “Delay,” and use
the Left and Right [
e
]/[
r
] but-
tons to select: 0 sec, 1 sec, 2 sec,
or 3 sec.
When 0 sec is selected, the trigger sig-
nal is output as soon as the input source
is changed.
5
Use the Up and Down [
q
]/[
w
] but-
tons to select an input source, and
use the Left and Right [
e
]/[
r
] but-
tons to select an option.
Off
:
No trigger signal is output.
A 12-volt trigger signal is output when
the connected component is selected as
the source for:
Main
:
Main room.
Zone2
:
Zone 2.
Main/Zone2
:
Main room or Zone 2.
Zone3
:
Zone 3.
Main/Zone3
:
Main room or Zone 3.
Zone2/Zone3
:
Zone 2 or Zone 3.
Main/Zone2/Zone3
:
Main room, Zone 2, or Zone 3.
6
When you’ve finished, press the
[SETUP] button.
Setup closes.
6-3. 12V Trigger A Setup
Delay
DVD
VCR/DVR
CBL/SAT
GAME/TV
AUX1
AUX2
TAPE
TUNER
CD
MOVE
VALUE
RETURN
RETURN
EXIT
SETUP
0sec
Main
Main
Main
Main
Main
Main
Main
Main
Main