Panasonic 55 Professional Display for Entry-Level Digital Signage Operating In - Page 22

IR IN/IR OUT terminal connection, IR IN, IR OUT

Page 22 highlights

Basic format for control data The transmission of control data from the computer starts with a STX signal, followed by the command, the parameters, and lastly an ETX signal in that order. If there are no parameters, then the parameter signal does not need to be sent. STX C1 C2 C3 : P1 P2 P3 P4 P5 ETX Start (02h) Colon End (03h) 3-character command (3 bytes) Parameter(s) Command Command Parameter Control details PON None Power ON POF AVL None *** Power OFF Volume 000 - 100 AMT IMS 0 1 None Audio MUTE OFF Audio MUTE ON Input select (toggle) HM1 HDMI 1 input (HDMI1) HM2 HDMI 2 input (HDMI2) DL1* DIGITAL LINK input (DIGITAL LINK) DV1 DVI-D IN input (DVI-D) PC1 PC IN input (PC) VD1 VIDEO input (VIDEO) COMPONENT input YP1 (COMPONENT/ RGB IN) UD1 USB input (USB) *: LF80 series only Note ● If multiple commands are transmitted, be sure to wait for the response for the first command to come from this unit before sending the next command. ● If an incorrect command is sent by mistake, this unit will send an "ER401" command back to the computer. ● In Standby condition (power OFF with remote control), the unit responds to PON command only. ● Consult your local Panasonic dealer for detail instructions on command usage. For more details, visit the following web site. http://panasonic.net/prodisplays/ IR OUT IR IN IR IN/IR OUT terminal connection Connect the mini plug (M3) cable from the IR OUT terminal of the first display to the IR IN terminal of the second display. The infrared signal of the first display is sent to the second display. In this case, the IR (infrared ray reception on the remote control sensor) on the second display does not operate. Repeating the above connections enables the daisy chain connection. Note ● Connection cables are not supplied with this unit. ● Daisy chain connection is possible only between the displays of the same series. Stereo mini plug (M3) cable (commercially available) First display Second display Third display IR OUT IR IN IR OUT IR IN 22 English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

English
22
Basic format for control data
The transmission of control data from the computer
starts with a STX signal, followed by the command, the
parameters, and lastly an ETX signal in that order. If
there are no parameters, then the parameter signal does
not need to be sent.
STX
C1 C2 C3
P1 P2 P3 P4
:
P5
ETX
Start
(02h)
3-character command
(3 bytes)
Colon
Parameter(s)
End
(03h)
Command
Command
Parameter
Control details
PON
None
Power ON
POF
None
Power OFF
AVL
***
Volume 000 - 100
AMT
0
Audio MUTE OFF
1
Audio MUTE ON
IMS
None
Input select (toggle)
HM1
HDMI 1 input
(HDMI1)
HM2
HDMI 2 input
(HDMI2)
DL1
*
DIGITAL LINK input
(DIGITAL LINK)
DV1
DVI-D IN input
(DVI-D)
PC1
PC IN input (PC)
VD1
VIDEO input
(VIDEO)
YP1
COMPONENT input
(COMPONENT/
RGB IN)
UD1
USB input (USB)
*
: LF80 series only
Note
If multiple commands are transmitted, be sure to wait
for the response for the first command to come from
this unit before sending the next command.
If an incorrect command is sent by mistake, this
unit will send an “ER401” command back to the
computer.
In Standby condition (power OFF with remote
control), the unit responds to PON command only.
Consult your local Panasonic dealer for detail
instructions on command usage.
For more details, visit the following web site.
http://panasonic.net/prodisplays/
IR IN/IR OUT terminal connection
Connect the mini plug (M3) cable from the IR OUT
terminal of the first display to the IR IN terminal of the
second display.
The infrared signal of the first display is sent to the
second display.
In this case, the IR (infrared ray reception on the remote
control sensor) on the second display does not operate.
Repeating the above connections enables the daisy
chain connection.
Note
Connection cables are not supplied with this unit.
Daisy chain connection is possible only between the
displays of the same series.
IR IN
IR OUT
IR IN
IR OUT
IR IN
IR OUT
Stereo mini plug (M3) cable (commercially available)
First display
Second display
Third display