Panasonic EYFMA2C Owner s Manual - Page 18

Setting the tool to configuration

Page 18 highlights

EN Setting the tool to configuration mode 1. Turn off the control panel. • If the control panel is on, remove and then reinsert the battery pack. 2. Engage the switch while pushing the button and then release both the button and the switch. • After all the LED lamps have turned off, the control panel will flash and change to configuration mode. [Fig.20] NOTE: • Tools ship from the factory set to "F" mode (torque control function off). • The control panel will turn off if the tool is not operated for a period of 5 minutes. Configuring the torque clutch setting [Fig.21] 1. Press the and buttons to select the clutch setting that is appropriate for the work being performed. [EYFLA4, EYFLA5, EYFLA6, EYFMA1] As the button is pressed As the button is pressed 29 30 F 1 2 28 ... 3 • "F" indicates that the torque control function is off. • You can select from 30 torque clutch settings (1 to 30). [EYFLA7, EYFLA8, EYFLA9, EYFMA2] As the button is pressed As the button is pressed 39 40 F 1 2 38 ... 3 • "F" indicates that the torque control function is off. • You can select from 40 torque clutch settings (1 to 40). •Use figures from the Tightening Torque Chart to guide your selection of torque clutch setting. (See the following tightening torque chart) 2. Press the OK button to accept the selected torque clutch setting. • The control panel will stop flashing and light up. CAUTION: • You must press the OK button in order for the selected setting to take effect. • Be sure to verify the new value after changing the setting. Tightening Torque Chart (for Reference Use) The values illustrated on this chart were measured under the conditions described below and are provided for reference purposes. Actual tightening torque varies with ambient conditions (the particular bolt being tightened, hardware being used, method of holding the bolt in place, etc.). [EYFLA4, EYFLA5, EYFLA6, EYFMA1] [Fig.22] [EYFLA7, EYFLA8, EYFLA9, EYFMA2] [Fig.23] Measurement conditions • Temperature: Room temperature (20°C/68°F) Setting the snug point detection level [Fig.24] 1. Press the A button. • The snug point detection level setting value will be displayed. [Fig.25] 2. Press the and buttons to set the best snug point detection level for the work you're performing. 3. Press the OK button to accept the number of torque stages and the snug point detection level. The tool's panel will flash and then light up continuously. - 18 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

-
18
-
EN
Setting the tool to configuration
mode
1. Turn off the control panel.
• If the control panel is on, remove
and then reinsert the battery pack.
2. Engage the switch while pushing the
button and then release both the
button and the switch.
• After all the LED lamps have turned
off, the control panel will flash and
change to configuration mode.
[Fig.20]
NOTE:
• Tools ship from the factory set to “F”
mode (torque control function off).
• The control panel will turn off if the
tool is not operated for a period of 5
minutes.
Configuring the torque clutch setting
[Fig.21]
1. Press the
and
buttons to select
the clutch setting that is appropriate
for the work being performed.
[EYFLA4, EYFLA5, EYFLA6, EYFMA1]
3
28
1
F
30
2
29
As the
button
is pressed
As the
button
is pressed
• “F” indicates that the torque control
function is off.
• You can select from 30 torque clutch
settings (1 to 30).
[EYFLA7, EYFLA8, EYFLA9, EYFMA2]
3
38
1
F
40
2
39
As the
button
is pressed
As the
button
is pressed
• “F” indicates that the torque control
function is off.
• You can select from 40 torque clutch
settings (1 to 40).
• Use figures from the Tightening
Torque Chart to guide your selection
of torque clutch setting. (See the fol-
lowing tightening torque chart)
2. Press the OK button to accept the
selected torque clutch setting.
• The control panel will stop flashing
and light up.
CAUTION:
You must press the OK button in order
for the selected setting to take effect.
• Be sure to verify the new value after
changing the setting.
Tightening Torque Chart (for Reference
Use)
Th
e values illustrated on this chart were
measured under the conditions described
below and are provided for reference pur-
poses. Actual tightening torque varies with
ambient conditions (the particular bolt being
tightened, hardware being used, method of
holding the bolt in place, etc.).
[EYFLA4, EYFLA5, EYFLA6, EYFMA1]
[Fig.22]
[EYFLA7, EYFLA8, EYFLA9, EYFMA2]
[Fig.23]
Measurement conditions
• Temperature: Room temperature
(20°C/68°F)
Setting the snug point detection level
[Fig.24]
1. Press the A button.
• The snug point detection level setting
value will be displayed.
[Fig.25]
2. Press the
and
buttons to set the
best snug point detection level for the
work you’re performing.
3. Press the OK button to accept the
number of torque stages and the
snug point detection level.
The tool’s panel will flash and then light