MAINTENANCE AND TROUBLESHOOTING Inspect and tighten all parts of the exercise bike regularly. Replace any worn parts immediately. To clean the exercise bike, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damage to the console, keep liquids away from the console and keep the console out of direct sunlight. CONSOLE TROUBLESHOOTING If the console does not turn on, make sure that the power adapter is fully plugged in. If lines appear in the console display, see HOW TO CHANGE CONSOLE SETTINGS on page 24 and adjust the contrast level of the display. If the handgrip heart rate monitor does not function properly, see step 5 on page 19. Next, locate the Reed Switch (46). Rotate the Pulley (29) until a Pulley Magnet (30) is aligned with the Reed Switch. Loosen, but do not remove, the indicated M4 x 16mm Screw (77). Slide the Reed Switch slightly toward or away from the Pulley Magnet. 29 77 46 30 HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, first unplug the power adapter. Using a flat screw- driver, release the tabs at the front and 44 along the sides of the Top Shield (44). Then, slide the Top Shield upward. Then, retighten the M4 x 16mm Screw (77). Plug in the power adapter and turn the Pulley (29) for a moment. Repeat these actions until the console displays correct feedback. When the reed switch is correctly adjusted, reattach the top shield and then plug in the power adapter. 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

25
Inspect and tighten all parts of the exercise bike
regularly. Replace any worn parts immediately.
To clean the exercise bike, use a damp cloth and a
small amount of mild soap.
IMPORTANT: To avoid
damage to the console, keep liquids away from
the console and keep the console out of direct
sunlight.
CONSOLE TROUBLESHOOTING
If the console does not turn on, make sure that the
power adapter is fully plugged in. If lines appear in the
console display, see HOW TO CHANGE CONSOLE
SETTINGS on page 24 and adjust the contrast level
of the display.
If the handgrip heart rate monitor does not function
properly, see step 5 on page 19.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the reed
switch, first unplug
the power adapter.
Using a flat screw-
driver, release the
tabs at the front and
along the sides of
the Top Shield (44).
Then, slide the Top
Shield upward.
Next, locate the Reed Switch (46). Rotate the Pulley
(29) until a Pulley Magnet (30) is aligned with the Reed
Switch. Loosen, but do not remove, the indicated M4
x 16mm Screw (77). Slide the Reed Switch slightly
toward or away from the Pulley Magnet.
Then, retighten the M4 x 16mm Screw (77). Plug in the
power adapter and turn the Pulley (29) for a moment.
Repeat these actions until the console displays correct
feedback.
When the reed switch is correctly adjusted, reattach
the top shield and then plug in the power adapter.
46
29
77
44
30