MAINTENANCE AND TROUBLESHOOTING Inspect and tighten all parts of the elliptical regularly. Replace any worn parts immediately. To clean the elliptical, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damage to the console, keep liquids away from the console 38 and keep the console out of direct sunlight. 39 CONSOLE TROUBLESHOOTING 78 78 If the console does not turn on, make sure that the power cord is fully plugged in. If the console does not display your heart rate when you hold the handgrip heart rate monitor, or if the displayed heart rate appears to be too high or too low, see step 5 on page 17. HOW TO CALIBRATE THE RAMP If the ramp is not functioning properly, the ramp may need to be calibrated. To calibrate the ramp, hold down the Calorie Workouts button for about 5 seconds until the display on the console changes. 78 Locate the Reed Switch (47). Loosen, but do not remove, the #8 x 1/2" Screw (91). Next, rotate the Large Pulley (17) until a Magnet (134) is aligned with the Reed Switch (47). Slide the Reed Switch slightly toward or away from the Magnet. Then, retighten the #8 x 1/2" Screw (91). Press the Calorie Workouts button once. The ramp calibration instructions will appear in the display. Press the Quick Ramp increase or decrease button to calibrate the ramp. The ramp will move upward and downward as it calibrates. 91 134 47 17 When the ramp stops moving, the ramp is calibrated. Then, press the Calorie Workouts button three times to return to the manual mode. HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, you must first remove the screws attaching the right shield (see the instructions below). Remove the indicated #8 x 3/4" Screws (78) from the Right and Left Shields (38, 39). Then, gently pull the Right Shield away from the frame. Rotate the Large Pulley (17) for a moment. Repeat these actions until the console displays correct feedback. When the reed switch is correctly adjusted, reattach the right shield. 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

25
Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap.
IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not turn on, make sure that the
power cord is fully plugged in.
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the dis-
played heart rate appears to be too high or too low, see
step 5 on page 17.
HOW TO CALIBRATE THE RAMP
If the ramp is not functioning properly, the ramp may
need to be calibrated. To calibrate the ramp, hold down
the Calorie Workouts button for about 5 seconds until
the display on the console changes.
Press the Calorie Workouts button once. The ramp
calibration instructions will appear in the display.
Press the Quick Ramp increase or decrease button to
calibrate the ramp. The ramp will move upward and
downward as it calibrates.
When the ramp stops moving, the ramp is calibrated.
Then, press the Calorie Workouts button three times to
return to the manual mode.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the reed switch, you must first remove the
screws attaching the right shield (see the instructions
below).
Remove the indicated #8 x 3/4" Screws (78) from the
Right and Left Shields (38, 39). Then, gently pull the
Right Shield away from the frame.
Locate the Reed Switch (47). Loosen, but do not
remove, the #8 x 1/2" Screw (91).
Next, rotate the Large Pulley (17) until a Magnet (134)
is aligned with the Reed Switch (47). Slide the Reed
Switch slightly toward or away from the Magnet. Then,
retighten the #8 x 1/2" Screw (91).
Rotate the Large Pulley (17) for a moment. Repeat
these actions until the console displays correct
feedback.
When the reed switch is correctly adjusted, reattach
the right shield.
MAINTENANCE AND TROUBLESHOOTING
78
78
78
38
39
17
134
91