Ricoh IS760 Operating Instructions - Page 14
DIP Switches, Important - scanner
View all Ricoh IS760 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
Guide to Components DIP Switches Change only the switches No. 1 to 3. Do not change the other switches. 1 ADC005S SW No. Function OFF ON 1 SCAM *1 disable enable 2 SCSI synchronous transmission enable disable 3 SCSI termination enable disable 4 5 6 (system usage) 7 always OFF Do not make changes. 8 *1 SCAM: SCSI Configured Automatically. Protocol to set SCSI ID automatically. Important ❒ SCSI ID will not be configured even if you set SCAM to enable, when more than one of this scanner with the SCAM function enabled are connected to the daisy chain. In this case, disable the SCAM by setting the DIP Switch No.1 ON, and set the SCSI ID with the Rotary Switch. ❒ The USB and the optional IEEE1394 connection cannot be used when the SCSI synchronous transmission is set. You can turn the DIP Switch No.2 OFF (SCSI synchronous transmission enabled) when using the scanner only with the SCSI connection. ❒ A malfunction with SCSI synchronous transmission may occur if you use a SCSI cable longer than recommended, or a cable out of the standard. In that case, turn the DIP Switch No.2 ON (SCSI synchronous transmission disabled). ❒ When the scanner is connected to the middle of the daisy chain, set the DIP Switch No.3 ON. 10