Ryobi RYi4022X Operation Manual - Page 15

Features

Page 15 highlights

FEATURES PRODUCT SPECIFICATIONS ENGINE Engine Type 212cc OHV REPLACEMENT SPARK PLUG Manufacturing # 099930627 or 099930667 LG F6RTC or equivalent Manufacturing # 099930628 or 095930628 TORCH F7TC or equivalent Engine Lubricant Volume approximately 18 oz. Fuel Volume 3.3 gal. GENERATOR Rated Voltage 120V Rated Amps 25.83A Rated Output 3,100 W Starting Watts 4,000 W Rated Frequency 60 Hz *Rated output determined by PGMA Standard G300 KNOW YOUR GENERATOR See Figure 1. The safe use of this product requires an understanding of the information on the product and in this operator's manual as well as a knowledge of the project you are attempting. Before use of this product, familiarize yourself with all o­ perating features and safety rules. 120 V AC RECEPTACLES Your generator has four single phase, 60 Hz outlets that are 120 Volt AC, 20 Amp receptacles and one 120 Volt AC 30 Amp RV receptacle. These can be used for operating appropriate appliances, electrical lighting, tools, and motor loads. AC CIRCUIT BREAKER The circuit breaker is provided to protect the generator against electrical overload. The circuit breaker may be reset by pressing the circuit breaker reset button. AIR FILTER The air filter helps to limit the amount of dirt and dust drawn into the unit during operation. ANSI/UL-2201 CERTIFIED This generator complies with the ANSI/UL-2201 Standard for Low Carbon Monoxide (CO) Emission Rates for portable generators. When used properly, portable generators with lowered CO emissions and CO shutoff capability mitigate the risk of CO related poisoning. DANGER: ANSI/UL 2201 compliance is not a substitute for safe generator practices. Always operate the generator in open, outdoor areas, at least 20 feet away from occupied structures. Never operate the generator near open windows, doors, or other unventilated spaces. AUTO IDLE SWITCH The auto idle switch is used to control the speed of the engine and conserve fuel. When the switch is in the ON (I) position and no appliances are connected to the unit, the engine will idle. If an appliance is added, the engine speed will increase to power the item. If the appliance is removed, the engine will return to idle. AUTOMATIC SHUTOFF The generator's carbon monoxide sensor is designed to monitor the level of carbon monoxide present during generator operation. If the unit is positioned incorrectly and carbon monoxide levels rise to an unsafe level, the LED on the sensor will flash red and the generator will automatically shut down. Leave the area immediately and relocate to an open outdoor area. Ventilate the area thoroughly before occupying again. Ensure the generator is located in an open, outdoor area at least 20 feet away from all doors, windows, and occupied spaces, and point exhaust away from occupied structures before restarting. NOTE: After a shutoff event has occured, the LED will continue to flash red for up to 20 minutes. Once the generator is relocated and CO levels are safe, the generator can be restarted even if the light is still flashing. FUEL TANK The fuel tank has a capacity of 3.3 gallons. GROUND TERMINAL The ground terminal is used to assist in properly grounding the generator to help protect against electrical shock. Consult with a qualified local electrician for grounding requirements in your area. LOW OIL SHUT DOWN PROTECTOR The low oil sensor causes the engine to stop if the level of lubricant in the crankcase is insufficient. The engine may not be restarted until sufficient engine lubricant has been added to the generator. 11 - English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

11 — English
FEATURES
KNOW YOUR GENERATOR
See Figure 1.
The safe use of this product requires an understanding of the
information on the product and in this operator’s manual as
well as a knowledge of the project you are attempting. Before
use of this product, familiarize yourself with all
operating
features and safety rules.
120 V AC RECEPTACLES
Your generator has four single phase, 60 Hz outlets that
are 120 Volt AC, 20 Amp receptacles and one 120 Volt AC
30 Amp RV receptacle. These can be used for operating
appropriate appliances, electrical lighting, tools, and motor
loads.
AC CIRCUIT BREAKER
The circuit breaker is provided to protect the generator
against electrical overload. The circuit breaker may be reset
by pressing the circuit breaker reset button.
AIR FILTER
The air filter helps to limit the amount of dirt and dust drawn
into the unit during operation.
ANSI/UL-2201 CERTIFIED
This generator complies with the ANSI/UL-2201 Standard
for Low Carbon Monoxide (CO) Emission Rates for portable
generators.
When used properly, portable generators with
lowered CO emissions and CO shutoff capability mitigate
the risk of CO related poisoning.
DANGER:
ANSI/UL 2201 compliance is not a substitute for safe
generator practices. Always operate the generator in
open, outdoor areas, at least 20 feet away from occu-
pied structures. Never operate the generator near open
windows, doors, or other unventilated spaces.
AUTO IDLE SWITCH
The auto idle switch is used to control the speed of the
engine and conserve fuel. When the switch is in the
ON (I)
position and no appliances are connected to the unit, the
engine will idle. If an appliance is added, the engine speed
will increase to power the item. If the appliance is removed,
the engine will return to idle.
AUTOMATIC SHUTOFF
The generator’s carbon monoxide sensor is designed to
monitor the level of carbon monoxide present during genera-
tor operation. If the unit is positioned incorrectly and carbon
monoxide levels rise to an unsafe level, the LED on the sensor
will flash red and the generator will automatically shut down.
Leave the area immediately and relocate to an open outdoor
area. Ventilate the area thoroughly before occupying again.
Ensure the generator is located in an open, outdoor area at
least 20 feet away from all doors, windows, and occupied
spaces, and point exhaust away from occupied structures
before restarting.
NOTE:
After a shutoff event has occured, the LED will con-
tinue to flash red for up to 20 minutes. Once the generator
is relocated and CO levels are safe, the generator can be
restarted even if the light is still flashing.
FUEL TANK
The fuel tank has a capacity of 3.3 gallons.
GROUND TERMINAL
The ground terminal is used to assist in properly grounding
the generator to help protect against electrical shock. Con-
sult with a qualified local electrician for grounding require-
ments in your area.
LOW OIL SHUT DOWN PROTECTOR
The low oil sensor causes the engine to stop if the level of
lubricant in the crankcase is insufficient. The engine may
not be restarted until sufficient engine lubricant has been
added to the generator.
PRODUCT SPECIFICATIONS
ENGINE
Engine Type
.......................................................
212cc OHV
REPLACEMENT SPARK PLUG
Manufacturing # 099930627 or
099930667
................................
LG F6RTC or equivalent
Manufacturing # 099930628 or
095930628
...............................
TORCH F7TC or equivalent
Engine Lubricant Volume
...................
approximately 18 oz.
Fuel Volume
..............................................................
3.3 gal.
GENERATOR
Rated Voltage
..............................................................
120V
Rated Amps
..............................................................
25.83A
Rated Output*
.........................................................
3,100 W
Starting Watts
.........................................................
4,000 W
Rated Frequency
........................................................
60 Hz
*Rated output determined by PGMA Standard G300