Samsung RF31FMESBSR User Manual Ver.0.4 (English, French, Spanish) - Page 15

Connecting to the water supply line, Connecting the water supply line to, the refrigerator.

Page 15 highlights

If the refrigerator is installed in an area with low water pressure (below 20psi), you can install a booster pump to compensate for the low pressure. After you have connected the water line, make sure the water storage tank inside the refrigerator is properly filled. To do this, press the water dispenser lever until the water runs from the water outlet. Water line installation kits are available at extra cost from your dealer. We recommend using a water line installation kit that contains copper tubing and ¼" compression nut. Connecting the water supply line to the refrigerator. There are several items that you need to purchase to complete this connection. You may find these items sold as a kit at your local hardware store. Use Copper Tubing • ¼" copper tubing • ¼" compression nut (1pc) • Ferrule (2pc) Use Plastic Tubing • ¼" plastic tubing → Molded end(Bulb) • ¼" compression nut (1pc) 01 SETTING UP Connecting to the water supply line 1. First, shut off the main water supply. 2. Locate the nearest cold water drinking line and install the pipe clamp and shut off valve. Cold water line Pipe clamp Shut off valve Refrigerator Compression Nut (1/4") (Assembled) Plastic Tubing (Assembled) Compression Fitting (Assembled) Ferrule (Not supplied) Molded end(Bulb) Compression nut (B) (1/4") (Not supplied) Copper tubing or Plastic tubing (B) (Not supplied) (Not supplied) Household water supply line 3. Connect the water line installation kit to the shut off valve. Cold water line Pipe clamp Shut off valve Water line installation kit 1. Connect the household water line to the assembled compression fitting. - If you are using copper tubing, slip the compression nut ( B ) (not supplied) and ferrule (not supplied) on the copper tubing (not supplied) as shown. - If you are using plastic tubing ( B ) , insert the molded end (Bulb) of the plastic tubing ( B ) into the compression fitting. Do not use without the molded end (Bulb) CAUTION of the plastic tubing ( B ). 2. Tighten the compression nut ( B ) onto the compression fitting. Do not over-tighten the compression nut ( B ) . 3. Turn the water on and check for any leakage. If you find water drops or leakage in the connection areas, turn off the main water supply. Check the connections and, if necessary, tighten. 4. Flush 1 gallon of water through the filter setting up _15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156

setting up
_15
01 SETTING UP
If the refrigerator is installed in an area with low
water pressure (below 20psi), you can install
a booster pump to compensate for the low
pressure.
After you have connected the water line, make
sure the water storage tank inside the refrigerator
is properly filled. To do this, press the water
dispenser lever until the water runs from the water
outlet.
Water line installation kits are available at
extra cost from your dealer.
We recommend using a water line
installation kit that contains copper tubing
and ¼” compression nut.
Connecting to the water supply line
1.
First, shut off the main water
supply.
2.
Locate the nearest cold water drinking line and
install the pipe clamp and shut off valve.
3.
Connect the water line installation kit to the
shut off valve.
Connecting the water supply line to
the refrigerator.
There are several items that you need to purchase
to complete this connection.
You may find these items sold as a kit at your local
hardware store.
Use Copper Tubing
Use Plastic Tubing
• ¼” copper tubing
• ¼” compression nut
(1pc)
• Ferrule (2pc)
• ¼” plastic tubing
Molded end(Bulb)
• ¼” compression nut
(1pc)
1.
Connect the household water line to the
assembled compression fitting.
-
If you are using copper tubing, slip the
compression nut (
B
) (not supplied) and
ferrule (not supplied) on the copper tubing (not
supplied) as shown.
-
If you are using plastic tubing (
B
) , insert the
molded end (Bulb) of the plastic tubing (
B
)
into the compression fitting.
Do not use without the molded end (Bulb)
of the plastic tubing (
B
).
2.
Tighten the compression nut (
B
) onto the
compression fitting.
Do not over-tighten the compression nut (
B
) .
3.
Turn the water on and check for any leakage.
If you find water drops or leakage in the
connection areas, turn off the main water
supply. Check the connections and, if
necessary, tighten.
4.
Flush 1 gallon of water through the filter
CAUTION
Pipe clamp
Pipe clamp
Cold water line
Cold water line
Shut off valve
Shut off valve
Shut off valve
Shut off valve
Pipe clamp
Pipe clamp
Cold water line
Cold water line
Water line installation kit
Water line installation kit
Compression
Compression
Nut (1/4”)
Nut (1/4”)
(Assembled)
(Assembled)
Ferrule
Ferrule
(Not supplied)
(Not supplied)
Plastic Tubing
Plastic Tubing
(Assembled)
(Assembled)
Compression
Compression
Fitting
Fitting
(Assembled)
(Assembled)
Molded
Molded
end(Bulb)
end(Bulb)
Compression
Compression
nut (B) (1/4”)
nut (B) (1/4”)
(Not supplied)
(Not supplied)
or
or
Copper tubing
Copper tubing
(Not supplied)
(Not supplied)
Plastic tubing (B)
Plastic tubing (B)
(Not supplied)
(Not supplied)
Household water supply line
Household water supply line
Refrigerator