Sanyo PLC-HF10000L Owner's Manual - Page 98

Status Read Commands, CR [Command] [CR]

Page 98 highlights

Appendix Status Read Commands Format The command is sent from PC to the projector with the format below; "CR" [Command] [CR] Command: one character (refer to the command table below.) The projector decodes the command and returns the 'Character string' with the format below; Command CR0 CR6 Function Status Read Temperature Read Return value 00 80 40 20 10 28 24 04 21 81 88 2C 8C %1 %2 Projector status Power On Stand-by mode Countdown Cooling down Power Malfunction Cooling down at the temperature anomaly Cooling down at Power Management mode Power Management mode after Cooling down Cooling down after the projector is turned off when the lamps are out. Stand-by mode after Cooling down when the lamps are out. Stand-by mode after Cooling down at the temperature anomaly. Cooling down when the projector is turned off by the shutter management function. Stand-by mode after Cooling down by the shutter management function. %1 = Temperature at Sensor 1 (˚C) %2 = Temperature at Sensor 2 (˚C) (ex.) %1 = 12.3 (˚C), %2 = 23.4 (˚C) --> The projector returns " 12.3 23.4". (F or each sensor, two digit and the tenth place numbers are displayed with a space between each temperature.) ? Communication failure The tables on page 97 and 98 show the typical command lists for controlling the projector. Please consult your local dealer for further information of other commands. 98

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Appendix
Status Read Commands
The command is sent from PC to the projector with
the format below;
“CR” [Command] [CR]
Command: one character (refer to the command
table below.)
The projector decodes the command and returns the
'Character string' with the format below;
Format
Command
Function
Return
value
Projector status
CR0
Status Read
00
Power On
80
Stand-by mode
40
Countdown
20
Cooling down
10
Power Malfunction
28
Cooling down at the temperature anomaly
24
Cooling down at Power Management mode
04
Power Management mode after Cooling down
21
Cooling down after the projector is turned off when the lamps
are out.
81
Stand-by mode after Cooling down when the lamps are out.
88
Stand-by mode after Cooling down at the temperature
anomaly.
2C
Cooling down when the projector is turned off by the shutter
management function.
8C
Stand-by mode after Cooling down by the shutter
management function.
CR6
Temperature Read
%1 %2
%1 = Temperature at Sensor 1 (˚C)
%2 = Temperature at Sensor 2 (˚C)
(ex.) %1 = 12.3 (˚C), %2 = 23.4 (˚C)
--> The projector returns “ 12.3
23.4”
.
(For each sensor, two digit and the tenth place numbers are
displayed with a space between each temperature.)
?
Communication failure
The tables on page 97 and 98 show the typical command lists for controlling the projector.
Please consult your
local dealer for further information of other commands.