Sennheiser HDE 2020-D-II Instruction manual Tourguide 2020-D - Page 69

EZL 2020-20 L charging case Art. No.: 500542, L 2021-40 charger, Tourguide 2020-D, Specifications

Page 69 highlights

Specifications EZL 2020-20 L charging case (Art. No.: 500542) Temperature range during charging Mains voltage Primary power consumption Charging voltage for HDE 2020-D-II Charging current per charging compartment for HDE 2020-D-II Charging time HDE 2020-D-II Charging time EK 2020-D-II Charging voltage for SK 2020-D / BA 2015 Charging current per charging compartment for SK 2020-D / BA 2015 Charging time SK 2020-D / BA 2015 Dimensions Weight (empty) 0 - 40 °C 100 - 240 V ~ (50/60 Hz) max. 70 W typ. 5 V typ. 400 mA approx. 2,5 h approx. 5 h max. 3.4 V typ. 500 mA approx. 3.5 h approx. 600 x 270 x 380 mm approx. 8300 g L 2021-40 charger Temperature range during charging Mains socket Mains voltage Primary power consumption Charging voltage per charging compartment Charging current per charging compartment Charging time for HDE 2020-D-II Charging time for EK 2020-D-II Dimensions Weight (empty) 3 - 40 °C 3-pin, protection class I, as per IEC/EN 60320-1 100 - 240 V ~ (50/60 Hz) max. 150 W typ. 5 V max. 400 mA approx. 2,5 h approx. 5 h approx. 483 x 399 x 172 mm approx. 8800 g 68 | Tourguide 2020-D

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77

68 | Tourguide 2020-D
Specifications
EZL 2020-20 L charging case (Art. No.: 500542)
Temperature range during charging
0 – 40
 
°C
Mains voltage
100 – 240
 
V
 
~ (50/60
 
Hz)
Primary power consumption
max� 70
 
W
Charging voltage for HDE 2020-D-II
typ� 5
 
V
Charging current per charging compartment for
HDE 2020-D-II
typ� 400
 
mA
Charging time HDE 2020-D-II
approx� 2,5
 
h
Charging time EK 2020-D-II
approx� 5
 
h
Charging voltage for SK 2020-D / BA 2015
max� 3�4
 
V
Charging current per charging compartment for
SK 2020-D / BA 2015
typ� 500
 
mA
Charging time SK 2020-D / BA 2015
approx� 3�5
 
h
Dimensions
approx� 600 x 270 x
380
 
mm
Weight (empty)
approx� 8300
 
g
L 2021-40 charger
Temperature range during charging
3 – 40 °C
Mains socket
3-pin, protection class I,
as per IEC/EN 60320-1
Mains voltage
100 – 240
 
V
 
~ (50/60
 
Hz)
Primary power consumption
max� 150 W
Charging voltage per charging compartment
typ� 5 V
Charging current per charging compartment
max� 400 mA
Charging time for HDE 2020-D-II
approx� 2,5 h
Charging time for EK 2020-D-II
approx� 5 h
Dimensions
approx� 483 x 399 x
172
 
mm
Weight (empty)
approx� 8800
 
g