(AR-407) All must be set to "6". (AR-507) Set default value 5. AR-287/337 AR-407/507 (AR-507) All must be set to "5." 61 - 4 Purpose Function (Purpose) Section Item Operation/ Procedure Adjustment Used to adjust the scanner (exposure) laser power (absolute value) in the printer mode. (For Photoconductor type B) Laser (Exposure) Operation (AR-287/337) Set default value 8. 67 67 - 18 Purpose Data clear Function Used to clear the application data area of the Network (Purpose) Scanner of the Flash ROM. Item Memory Operation/ 1. To clear data, press the [EXECUTE] key. Procedure Clear area: 0x8f060000/0x8f07ffff 2. The confirmation menu is displayed to confirm whether the ARNS1 area data in the Flash ROM are cleared or not. [YES] key: Clear [NO] key: Not clear 3. During clearing data, "NOW DOING . . ." is displayed. [No key entry is accepted during clearing.] 4. After normal completion, "END" is outputted. In case of any trouble, "NG" is outputted. [When the CA key is pressed, reset is performed.] (AR-407) Set default value 6. 7 - 57 3/13/2000