<Repeater control>, <Repeater control command>
UPC - 074000046719
View all Sharp PN-G655RUP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 41 highlights
ENGLISH Controlling the Monitor with a PC This system has a function to allow setting of multiple monitors connected in a daisy chain using a single command. This function is called repeater control. You can use Repeater control function without assigning ID numbers. [Example] Set 1 Set 2 Set 3 Set 4 PC If monitors are connected as shown above, you can execute a command like "Set all monitors' input settings to DVI: DIGITAL". Repeater control is achieved by setting the FOURTH CHARACTER of the parameter to "+". Example: VOLM030+ ← Sets volume of all monitors to 30. In repeater control, responses are returned by all the connected monitors. If you want to determine that a value has been returned by a specific set, assign ID numbers to each monitor in advance. When some monitors do not return their responses, the probable cause is that the monitors could not receive the command or command processing is not complete. Do not send a new command. Example: (When 4 monitors are connected, and assigned ID numbers: 1 through 4) VOLM030+ WAIT OK 001 OK 002 OK 003 OK 004 ← If 4 monitors are connected in a chain, reliable operation can be ensured by sending a new command only after a reply has been returned by 4th (last) monitor. Repeater control can also be used for reading settings. Example: VOLM???+ WAIT 10 001 20 002 30 003 30 004 Volume settings for all monitors are returned. TIPS • If repeater control is used during ID designation (IDSL, IDLK), the ID designation is canceled. 39 E