Sharp PN-G655RUP PN-655RU Operation Manual - Page 43
<Communication interval>
UPC - 074000046719
View all Sharp PN-G655RUP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
ENGLISH Controlling the Monitor with a PC If execution of the command is taking some time WA I T Return code (0DH, 0AH) When the following commands are used, "WAIT" is returned. In this case, a value will be returned if you wait a while. Do not send any command during this period. No ID number is attached to WAIT response. • Commands which return WAIT: - When repeater control is used - When an IDSL or IDLK command is used - When one of the following commands is used: RSET, INPS, ASNC, WIDE, EMAG, EPOS, PXSL, POWR, AGIN, MWIN, MWIP, MWPP. When control via RS-232C is locked (to prevent use) using the operation lock function (see page 32) L OCKE D Return code (0DH, 0AH) If the current parameter is read out using "?" for the parameter (for numerical values etc.) • Response when no ID number has been set Example: VOLM???? 10 • Response when an ID number has been set (In the example below: ID number = 1) Example: VOLM???? 10 001 • After OK or ERR is returned, you must send the following commands. To set a timeout for the command response, specify 10 seconds or longer. • Provide an interval of 100 ms or more between the command response and the transmission of the next command. VOLM0020 OK INPS0001 WAIT OK Interval of 100 ms or more 41 E