ERS-232C command table
UPC - 074000046719
View all Sharp PN-G655RUP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Controlling the Monitor with a PC RS-232C command table Command: Command field (See page 35.) Direction: W When the "Parameter" is set in the parameter field (see page 35), the command functions as described under "Control/Response Contents". R The returned value indicated under "Reply" can be obtained by setting "????", " ?" or "???+" (repeater control) in the parameter field (see page 35). Parameter: Parameter field (See page 35.) Reply: Response (Returned value) * "Yes" indicates commands which can be used in power standby mode. Power control/Input mode selection Control item Command Direction Parameter Reply Control/Response contents * POWER CONTROL POWR W 0 Switches to standby mode. 1 Returns from standby mode. R 0 Standby mode Yes 1 Normal mode 2 Input signal waiting mode INPUT MODE SELECTION INPS W 0 Toggle change for input mode 1 PC digital RGB (DVI) (DIGITAL) 2 PC analog RGB (ANALOG) 3 Component (COMPONENT) 4 VIDEO Yes R 1 PC digital RGB (DVI) (DIGITAL) 2 PC analog RGB (ANALOG) 3 Component (COMPONENT) 4 VIDEO E 42