HCD-C770/C990 2-7. Disc Check Memory Disc Check Memory 1. SL Disc check 2. SL Disc check 3. SL Disc check 3. MECHA AGING On the Test Mode Menu screen, selecting [3] executes the aging of the mechanism deck. ### Aging Test MENU ### Operation Menu 1. Open/Close Test Exit: RETURN On this screen, measure the mirror time of chucked disc, and write to the EEPROM. 2-8. Error Rate Display Error Rate Display UC CR ADD PI1 Err Now xx xxxx xxxxxxxx Max xx xxxx xxxxxxxx Avg xx xxxx xxxxxxxx PI2 Err Now xx xxxx xxxxxxxx Max xx xxxx xxxxxxxx Avg xx xxxx xxxxxxxx PO Err Now xx xxxx xxxxxxxx Max xx xxxx xxxxxxxx Avg xx xxxx xxxxxxxx Exit: RETURN On this screen, measure and display the error rate. UC : Incorrect value CR : Correct value Add : Address 2-9. SACD Water Mark Check SACD Water Mark Check PSP AMP PSN Start: ENTER Exit: RETURN On this screen, measure the PSP AMP value and PSN value of SACD water mark. Exit: RETURN 1) On the Aging Test MENU screen, press the [1] key on the remote commander to display the Open/Close Test screen. 2) Insert discs and press the [ENTER] key on the remote commander. 3) Is starts the aging. During aging, the disc number, operating status and repeat cycle are displayed. Aging can be aborted at any time by pressing the x key. After the operation is stopped, press the x key or [RETURN] key aging to return to the Aging Test MENU. 4. EMERGENCY HISTORY On the Test Mode Menu screen, selecting [4] displays the information such as servo emergency history. The history information from last 1 up to 10 can be scrolled with the O key or o key. Also, specific information can be displayed by directly entering that number with ten keys. ### EMG. History ### Laser Hours CD xxxxhxxm DVD xxxxhxxm a. bb xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx a. bb xx xx xx xx xx xx xx xx xx xx xx xx xx xx xx Select:1-9 Scroll:UP/DOWN (1.Latest EMG.) Exit: RETURN xxxxhxxm : The laser on total hours. Data below minutes are omitted. a. : Error number. bb : Error code. xx : Not used. • Clearing History Information Clearing laser hours: Press the [DVD DISPLAY] and [CLEAR] keys in this order. Then both CD and DVD data are cleared. Clearing emergency history: Press the [DVD TOP MENU] and [CLEAR] keys in this order. Initializing set up data: Press [DVD MENU] and [CLEAR] keys in this order. The data have been initialized when "Set Up Initialized" message is displayed. The EMG. History screen will be restored soon. 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142

29
HCD-C770/C990
2-7.
Disc Check Memory
Disc Check Memory
1. SL Disc check
2. SL Disc check
3. SL Disc check
Exit: RETURN
On this screen, measure the mirror time of chucked disc, and write
to the EEPROM.
2-8.
Error Rate Display
Error Rate Display
UC
CR ADD
PI1 Err
Now xx xxxx xxxxxxxx
Max xx xxxx xxxxxxxx
Avg xx xxxx xxxxxxxx
PI2 Err
Now xx xxxx xxxxxxxx
Max xx xxxx xxxxxxxx
Avg xx xxxx xxxxxxxx
PO
Err
Now xx xxxx xxxxxxxx
Max xx xxxx xxxxxxxx
Avg xx xxxx xxxxxxxx
Exit: RETURN
On this screen, measure and display the error rate.
UC
: Incorrect value
CR
: Correct value
Add : Address
2-9.
SACD Water Mark Check
SACD Water Mark Check
PSP AMP
PSN
Start: ENTER
Exit: RETURN
On this screen, measure the PSP AMP value and PSN value of SACD
water mark.
3.
MECHA AGING
On the Test Mode Menu screen, selecting
[3]
executes the aging of
the mechanism deck.
### Aging Test MENU ###
Operation Menu
1. Open/Close Test
Exit: RETURN
1)
On the Aging Test MENU screen, press the
[1]
key on the
remote commander to display the Open/Close Test screen.
2)
Insert discs and press the
[ENTER]
key on the remote
commander.
3)
Is starts the aging.
During aging, the disc number, operating status and repeat cycle
are displayed. Aging can be aborted at any time by pressing
the
x
key. After the operation is stopped, press the
x
key or
[RETURN]
key aging to return to the Aging Test MENU.
4.
EMERGENCY
HISTORY
On the Test Mode Menu screen, selecting
[4]
displays the
information such as servo emergency history.
The history information from last 1 up to 10 can be scrolled with
the
O
key or
o
key. Also, specific information can be displayed
by directly entering that number with ten keys.
### EMG. History ###
Laser Hours
CD
xxxxhxxm
DVD xxxxhxxm
a.
bb xx xx xx
xx xx xx xx
xx xx xx xx
xx xx xx xx
a.
bb xx xx xx
xx xx xx xx
xx xx xx xx
xx xx xx xx
Select:1-9
Scroll:UP/DOWN
(1.Latest EMG.)
Exit: RETURN
xxxxhxxm : The laser on total hours. Data below minutes are
omitted.
a.
: Error number.
bb
: Error code.
xx
: Not used.
Clearing History Information
Clearing laser hours:
Press the
[DVD°DISPLAY]
and
[CLEAR]
keys in this order.
Then both CD and DVD data are cleared.
Clearing emergency history:
Press the
[DVD°TOP°MENU]
and
[CLEAR]
keys in this order.
Initializing set up data:
Press
[DVD°MENU]
and
[CLEAR]
keys in this order.
The data have been initialized when “Set Up Initialized”
message is displayed. The EMG. History screen will be restored
soon.