Sony HDRC-4000 Operation Guide - Page 30
MOTION DETECTION, M/D/Y, name, No., Set value, Meaning, Y/Mn/D, 2 Mn/D, 3 D/M/Y
![]() |
View all Sony HDRC-4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Page name Page No. C07 C08 C09 Item CHANNEL A MODE Set value MOTION DETECTION, FIELD COMBINATION(Weave), FIELD EXTENSION(Bob), PsF CONVERSION MOTION THRESHOLD LOW, MID, HIGH CHANNEL B MODE MOTION DETECTION, FIELD COMBINATION(Weave), FIELD EXTENSION(Bob), PsF CONVERSION MOTION THRESHOLD LOW, MID, HIGH DATE/TIME 2013.**.** to 20**.**.** 00:00 to 23:59 FILE TIMESTAMP FORMAT 1 Y/Mn/D, 2 Mn/D, 3 D/M/Y, 4 D/M, 5 M/D/Y, 6 M/D TEMP WARNING PLD NG REFERENCE UNLOCK FAN STOP POWER SUPPLY UNIT OFF, ON OFF, ON OFF, ON OFF, ON OFF, ON Meaning Deinterlacing mode setting (converting from interlaced to progressive). (Enabled when the system format frame rate is 59.94 or 50) MOTION DETECTION: Detect motion, and apply FIELD EXTENSION(Bob) for areas with motion and FIELD COMBINATION(Weave) for areas without motion. FIELD COMBINATION(Weave): Create a single progressive frame using two continuous interlaced fields. FIELD EXTENSION(Bob): Create a single progressive frame using a single interlaced field and interpolating the missing line. PsF CONVERSION: Use for PsF input when converting to double frame rate. (Example: 29.97PsF input, 59.94P output) Set the motion detection threshold when MODE is set to MOTION DETECTION. (---) is displayed when MODE is not set to MOTION DETECTION. Deinterlacing mode setting (converting from interlaced to progressive). (Enabled when the system format frame rate is 59.94 or 50) MOTION DETECTION: Detect motion, and apply FIELD EXTENSION(Bob) for areas with motion and FIELD COMBINATION(Weave) for areas without motion. FIELD COMBINATION(Weave): Create a single progressive frame using two continuous interlaced fields. FIELD EXTENSION(Bob): Create a single progressive frame using a single interlaced field and interpolating the missing line. PsF CONVERSION: Use for PsF input when converting to double frame rate. (Example: 29.97PsF input, 59.94P output) Set the motion detection threshold when MODE is set to MOTION DETECTION. (---) is displayed when MODE is not set to MOTION DETECTION. Date and time settings Y: Year, Mn: Month (numeric), M: Month (English abbreviation), D: Day Set whether to output various status from pin 15 of the IO port A Logic OR (logical sum) to check for any of the following items set to ON is output from pin 15. Temperature is too high Access to PLD failed Not locked to external reference sync signal Fan stopped Exceeded the recommended operating time of the power supply unit 30
![](/manual_guide/products/sony-hdrc4000-operation-guide-104c100/30.png)