Sony HDW1800 Installation Manual - Page 27

Settings and Adjustment when External Equipment is Connected

Page 27 highlights

1-15. Settings and Adjustment when External Equipment is Connected 1-15-1. Settings for Time Code To set the TIME CODE, open the the P02 : TC page on the function menu. When Editing with an Editor (BVE-2000, etc.) Capable of the 1st Edit When this unit is used by connecting to an editor, set as follows. Button F1 F2 F3 Item (Display) TCG SOURCE (TCG SRC) TCG PRESET/REGEN (TCG MODE) TCG RUN (TCG RUN) Setting INTERNAL PRESET FREE When Editing with Direct Machine-to-Machine (VTR to VTR) n The setup menu ITEM-610 : REGEN CONTROL MODE setting data must be set to "AS&IN". Button F1 F2 F3 Item (Display) TCG SOURCE (TCG SRC) TCG PRESET/REGEN (TCG MODE) TCG RUN (TCG RUN) Setting INTERNAL PRESET FREE 1-15-2. VTR Constant Values Settings of Editor Set the VTR constant values according to the table 1-15-2 below when the editor which needs the setting of VTR constant values is connected. Moreover, the change of VTR constant values are required when the operation mode is switched by setup menu of this unit. n When remote-controlling this unit by the editor, set the setup menu ITEM-401: FUNCTION MODE AFTER CUE-UP to "STOP". Model HDW-1800, HDW-D1800 Table 1-15-2. VTR Constant Values Settings of Editor Operation VTR CONSTANT 1 VTR CONSTANT 2 Mode Data No. Data No. 123456 78 123456 78 59.94, 29.97P 20 E2 00 96 07 07 03 8A*1 0D 08 00 00 81 3D FF 5A 50, 25P 21 E2 00 7D 07 07 03 8A*1 0D 07 00 00 83 3B FF 4B 24P, 23.98P 22 E2 00 78 07 07 03 8A*1 0D 07 00 00 83 3B FF 4B (Standard value is expressed in hexadecimal.) *1: Set the data of No.8 of the VTR CONSTANT 1 to "0A" for the following editors. . BVE-900 ROM versions earlier than 1.08 . BVE-600 ROM versions earlier than 1.01 HDW-1800/D1800 1-21 (E)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

1-21 (E)
HDW-1800/D1800
1-15. Settings and Adjustment when External Equipment is Connected
1-15-1.
Settings for Time Code
To set the TIME CODE, open the the P02 : TC page on the function menu.
When Editing with an Editor (BVE-2000, etc.) Capable of the 1st Edit
When this unit is used by connecting to an editor, set as follows.
Button
Item (Display)
Setting
F1
TCG SOURCE (TCG SRC)
INTERNAL
F2
TCG PRESET/REGEN (TCG MODE)
PRESET
F3
TCG RUN (TCG RUN)
FREE
When Editing with Direct Machine-to-Machine (VTR to VTR)
n
The setup menu ITEM-610 : REGEN CONTROL MODE setting data must be set to
AS&IN
.
Button
Item (Display)
Setting
F1
TCG SOURCE (TCG SRC)
INTERNAL
F2
TCG PRESET/REGEN (TCG MODE)
PRESET
F3
TCG RUN (TCG RUN)
FREE
1-15-2.
VTR Constant Values Settings of Editor
Set the VTR constant values according to the table 1-15-2 below when the editor which needs the setting
of VTR constant values is connected. Moreover, the change of VTR constant values are required when
the operation mode is switched by setup menu of this unit.
n
When remote-controlling this unit by the editor, set the setup menu ITEM-401: FUNCTION MODE
AFTER CUE-UP to
STOP
.
Table 1-15-2. VTR Constant Values Settings of Editor
(Standard value is expressed in hexadecimal.)
*
1: Set the data of No.8 of the VTR CONSTANT 1 to
0A
for the following editors.
.
BVE-900 ROM versions earlier than 1.08
.
BVE-600 ROM versions earlier than 1.01
Model
Operation
Mode
VTR CONSTANT 1
1
2
3
4
5
6
7
8
Data No.
VTR CONSTANT 2
1
2
3
4
5
6
7
8
HDW-1800,
HDW-D1800
59.94, 29.97P
20
E2
00
96
07
07
03
8A
*
1
0D
08
00
00
81
3D
FF
5A
50, 25P
21
E2
00
7D
07
07
03
8A
*
1
*
1
0D
07
00
00
83
3B
FF
4B
24P, 23.98P
22
E2
00
78
07
07
03
8A
0D
07
00
00
83
3B
FF
4B
Data No.