Thermador KBUDT4865E User Manual - Page 19

Product Data Sheets - price

Page 19 highlights

PRODUCT DATA SHEETS Base Grille Water Filtration System Model WF-LC400V/LC400V Capacity 400 Gallons (1514 Liters) Tested and certified by NSF International against ANSI/NSF Standard 42 for the reduction of Chlorine Taste and Odor, Particulate Class I*; and against ANSI/NSF Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene, Toxaphene, p-dichlorobenzene, 2, 4-D, Cysts, Turbidity and Asbestos. This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42/53. Substance Reduction Aesthetic Effects Chlorine Taste/Odor Particulate Class 1* Contaminant Reduction Lead: @ pH 6.5 Lead: @ pH 8.5 Mercury: @ pH 6.5 Mercury: @ pH 8.5 Benzene p-dichlorobenzene Toxaphene Atrazine 2, 4-D Asbestos Cysts‡ Turbidity NSF Reduction Requirements ≥50% ≥85% NSF Reduction Requirements 0.01mg/L 0.01mg/L 0.002 mg/L 0.002 mg/L 0.005 mg/L 0.075 mg/L 0.003 mg/L 0.003 mg/L 0.07 mg/L 99% 99.95% 0.5 NTU Average Influent 2.1 mg/L 5,366,667/mL Average Influent 0.152 mg/L† 0.143 mg/L† 0.0061 mg/L 0.0057 mg/L 0.0162 mg/L 0.220 mg/L 0.014 mg/L 0.0086 mg/L 0.197 mg/L 26 x 107 111,000/mL 11.00 NTU Influent Challenge Concentration 2.0 mg/L ± 10% At least 10,000 particles/mL Influent Challenge Concentration 0.15 mg/L ± 10% 0.15 mg/L ± 10% 0.006 mg/L ± 10% 0.0058 mg/L ± 10% 0.015 ± 10% 0.225 ± 10% 0.015 ± 10% 0.009 mg/L ± 10% 0.210 ± 10% 107 to 108 fibers/L†† 50,000/L min. 11 ± 1 NTU Maximum Effluent 0.06 mg/L 4,100/mL** Average Effluent 0.05 mg/L 2,300/mL Minimum% Average% Reduction Reduction 97.1% 99.3% 97.6% 99.9% Maximum Effluent 0.001 mg/L 0.001 mg/L 0.0004 mg/L 0.0008 mg/L 0.0005 mg/L 0.0005 mg/L 0.0014 mg/L 0.0005 mg/L 0.058 mg/L 0.18 x 107 mg/L 1 mg/L 0.40 NTU Average Effluent 0.001 mg/L 0.001 mg/L 0.0003 mg/L 0.00051 mg/L 0.001 mg/L 0.0005 mg/L 0.001 mg/L 0.0005 mg/L 0.0137 mg/L 0.18 x 107 mg/L 1 mg/L 0.35 NTU Minimum% Average% Reduction Reduction 99.34% 99.30% 99.34% 99.30% 93.5% 85.8% 96.7% 91.2% 96.3% 96.3% 99.7% 99.7% 90% 92.96% 94.25% 94.25% 70.6% 93.06% 99.93 99.93% 99.99% 96.4% 99.99% 96.8% Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F (17.2°C). s It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised. s Model WF-LC400V The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter's rated life is used, the filter indicator light changes from green to yellow. When 100% of the filter's rated life is used, the filter indicator light changes from yellow to red, and it is recommended that you replace the filter. Use replacement cartridge LC400V, part: 2255709. 2006 suggested retail price of $39.99 U.S.A./ $49.95 Canada. Prices are subject to change without notice. s Refer to the front cover or "Accessories" section for the Manufacturer's name, address and telephone number. s Refer to the "Warranty" section for the Manufacturer's limited warranty. Application Guidelines/Water Supply Parameters Water Supply Water Pressure Water Temperature Service Flow Rate City or Well 30 - 120 psi (207 - 827 kPa) 33° - 100°F (0.6° - 37.8° C) 0.5 GPM (1.89 L/min.) @ 60 psi. s The product is for cold water use only. s Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. *Class I particle size: >0.5 to

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

19
PRODUCT DATA SHEETS
Base Grille Water Filtration System
Model WF-LC400V/LC400V Capacity 400 Gallons (1514 Liters)
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63
°
F
(17.2
°
C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-LC400V
The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter
s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter
s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge LC400V, part:
2255709. 2006 suggested retail price of $39.99 U.S.A./
$49.95 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
Refer to the front cover or
Accessories
section for the
Manufacturer
s name, address and telephone number.
Refer to the
Warranty
section for the Manufacturer
s limited
warranty.
Application Guidelines/Water Supply Parameters
Tested and certified by NSF International against ANSI/NSF Standard 42 for the
reduction of Chlorine Taste and Odor, Particulate Class I*; and against
ANSI/NSF Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene,
Toxaphene, p-dichlorobenzene, 2, 4-D, Cysts, Turbidity and Asbestos.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum%
Reduction
Average%
Reduction
Chlorine Taste/Odor
Particulate Class 1
*
50%
85%
2.1 mg/L
5,366,667/mL
2.0 mg/L ± 10%
At least 10,000
particles/mL
0.06 mg/L
4,100/mL**
0.05 mg/L
2,300/mL
97.1
%
99.3%
97.6%
99.9%
Contaminant
Reduction
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum%
Reduction
Average%
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
0.01mg/L
0.01mg/L
0.152 mg/L
0.143 mg/L
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.001 mg/L
0.001 mg/L
0.001 mg/L
0.001 mg/L
99.34%
99.30%
99.34%
99.30%
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.002 mg/L
0.002 mg/L
0.0061 mg/L
0.0057 mg/L
0.006 mg/L ± 10%
0.0058 mg/L ± 10%
0.0004 mg/L
0.0008 mg/L
0.0003 mg/L
0.00051 mg/L
93.5%
85.8%
96.7%
91.2%
Benzene
0.005 mg/L
0.0162 mg/L
0.015 ± 10%
0.0005 mg/L
0.001 mg/L
96.3%
96.3%
p-dichlorobenzene
0.075 mg/L
0.220 mg/L
0.225 ± 10%
0.0005 mg/L
0.0005 mg/L
99.7%
99.7%
Toxaphene
0.003 mg/L
0.014 mg/L
0.015 ± 10%
0.0014 mg/L
0.001 mg/L
90%
92.96%
Atrazine
0.003 mg/L
0.0086 mg/L
0.009 mg/L ± 10%
0.0005 mg/L
0.0005 mg/L
94.25%
94.25%
2, 4-D
0.07 mg/L
0.197 mg/L
0.210 ± 10%
0.058 mg/L
0.0137 mg/L
70.6%
93.06%
Asbestos
99%
26 x 10
7
10
7
to 10
8
fibers/L
††
0.18 x 10
7
mg/L
0.18 x 10
7
mg/L
99.93
99.93%
Cysts
Turbidity
99.95%
0.5 NTU
111,000/mL
11.00 NTU
50,000/L min.
11 ± 1 NTU
1 mg/L
0.40 NTU
1 mg/L
0.35 NTU
99.99%
96.4%
99.99%
96.8%
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33
°
- 100
°
F (0.6
°
- 37.8
°
C)
0.5 GPM (1.89 L/min.) @ 60 psi.
*
**
††
Class I particle size: >0.5 to <1 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
Fibers greater than 10 um in length
Based on the use of Cryptosporidium parvum oocysts
®
NSF is a registered trademark of NSF International.