External Dimensions

Page 17 highlights

2 Introduction No. Item 1 AC Input 2 Input Breaker 3 Fan 4 Output Receptacle 5 Accessory Slot 6 Ground Terminal 7 EPO/ROO Port 8 RS-232 Port* 9 USB Port Function Connects the UPS to the AC mains. Protects the utility power from further damage when the UPS fails. Refer to section 6.8 Input Breaker for more information. Cools and ventilates the UPS. Connect to your loads. Accepts an optional WEBCARDLX network interface card that enables full remote access. Refer to section 7 Communication Interfaces for more information. For grounding the UPS. Refer to section 7 Communication Interfaces for more information. Communication interface port. Refer to section 7 Communication Interfaces for more information. *SMC models do not include this feature Communication interface port. Refer to section 7 Communication Interfaces for detailed information. 2.4 External Dimensions 21.8 in. [554 mm] 17.3 in. 1.7 in. [440 mm] [44 mm] 20 in. [509 mm] 17.3 in. 1.7 in. [440 mm] [44 mm] Figure 2-1: 1.5kVA Exterior & Dimensions Figure 2-1: 700VA-1000VA Exterior & Dimensions 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

17
2 Introduction
No. Item
Function
1
AC Input
Connects the UPS to the AC mains.
2
Input Breaker
Protects the utility power from further damage when the UPS fails. Refer to section
6.8 Input
Breaker
for more information.
3
Fan
Cools and ventilates the UPS.
4
Output Receptacle
Connect to your loads.
5
Accessory Slot
Accepts an optional WEBCARDLX network interface card that enables full remote access. Refer
to section
7 Communication Interfaces
for more information.
6
Ground Terminal
For grounding the UPS.
7
EPO/ROO Port
Refer to section
7 Communication Interfaces
for more information.
8
RS-232 Port*
Communication interface port. Refer to section
7 Communication Interfaces
for more
information.
*SMC models do not include this feature
9
USB Port
Communication interface port. Refer to section
7 Communication Interfaces
for detailed
information.
2.4 External Dimensions
Figure 2-1:
1.5kVA Exterior & Dimensions
Figure 2-1: 700VA-1000VA Exterior & Dimensions
17.3 in.
[440 mm]
17.3 in.
[440 mm]
1.7 in.
[44 mm]
1.7 in.
[44 mm]
21.8 in.
[554 mm]
20 in.