Tripp Lite SMART1000RT1U Owners Manual for SmartPro Line-Interactive Single-Ph - Page 30

Technical Specifications

Page 30 highlights

12 Technical Specifications Model SMART700RT1U SMART750RT1U SMART1000RT1U SMC1000RT1U SMART1500RT1U SMC1500RT1U Nominal Voltage and Input Range 100V~, 120V~, 127V~, 80V-162V (High Sensitivity) 70V-162V (Low Sensitivity) Nominal Input Frequency and Tolerance 50 Hz (-4/+20 Hz for High Sensitivity; -10/+20 Hz for Low Sensitivity) 60 Hz (-4/+10 Hz) Nominal Output Voltage 120V~ in Line Mode and 120V~ in Battery Mode Nominal Output Frequency 50 Hz (-4/+20 Hz for High Sensitivity; -10/+20 Hz for Low Sensitivity) 60 Hz (-4/+10 Hz) Output Voltage Regulation in Line Mode 120V~ (-16%/+16%) Output voltage regulation in Battery Mode: 120V~ (-10%/+6%) Nominal output power in W / VA: 420W/700VA @ 120V~/127V~ 350W/583VA 100V~ 600W/750VA @ 120V~/127V~ 500W/625VA @ 100V~ 770W/1000VA @ 120V ~/127V~ 641W/833VA @ 100V~ 600W/1000VA @ 120V ~ /127V~ 500W/833VA @ 100V~ 1100W/1440VA @ 120V ~/127V~ 825W/1080VA (100V~) 1100W/1440VA @ 120V ~/127V~ 825W/1083VA (100V~) Output Voltage Waveform Sinusoidal in Line Mode and in Battery Mode Maximum Output Current @ P.F. 5.83A @ 100V~ 5.84A @ 120V~ 5.52A @ 127V~ 6.25A @ 100V~ 6.25A @120V~ 5.91A @127V~ 8.33A @ 100V~ 8.34A @120V~ 7.88A @ 127V~ 8.33A @ 100V~ 8.34A @120V~ 7.88A @ 127V~ 10.8A @ 100V~ 12A @ 120V~ 11.34A @ 127V~ 10.8A @ 100V~ 12A @ 120V~ 11.34A @ 127V~ P.F. = 0.6 P.F. = 0.8 P.F. = 0.8 P.F. = 0.6 P.F. = .76 P.F. = .76 Efficiency with Nominal Load 98% Maximum Operating Altitude at 100% of Nominal Power 3280 ft. (1000 m) Online Overload Capability

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

30
12 Technical Specifications
Model
SMART700RT1U
SMART750RT1U
SMART1000RT1U
SMC1000RT1U
SMART1500RT1U
SMC1500RT1U
Nominal Voltage
and Input Range
100V~, 120V~, 127V~, 80V-162V (High Sensitivity)
70V-162V (Low Sensitivity)
Nominal Input
Frequency and
Tolerance
50 Hz (-4/+20 Hz for High Sensitivity; -10/+20 Hz for Low Sensitivity)
60 Hz (-4/+10 Hz)
Nominal Output
Voltage
120V~ in Line Mode and 120V~ in Battery Mode
Nominal Output
Frequency
50 Hz (-4/+20 Hz for High Sensitivity; -10/+20 Hz for Low Sensitivity)
60 Hz (-4/+10 Hz)
Output Voltage
Regulation in Line
Mode
120V~ (-16%/+16%)
Output voltage
regulation in Battery
Mode:
120V~ (-10%/+6%)
Nominal output
power in W / VA:
420W/700VA @
120V~/127V~
350W/583VA
100V~
600W/750VA @
120V~/127V~
500W/625VA @
100V~
770W/1000VA @
120V ~/127V~
641W/833VA @
100V~
600W/1000VA @
120V ~ /127V~
500W/833VA @
100V~
1100W/1440VA @
120V ~/127V~
825W/1080VA
(100V~)
1100W/1440VA @
120V ~/127V~
825W/1083VA
(100V~)
Output Voltage
Waveform
Sinusoidal in Line Mode and in Battery Mode
Maximum Output
Current @ P.F.
5.83A @ 100V~
5.84A @ 120V~
5.52A @ 127V~
6.25A @ 100V~
6.25A @120V~
5.91A @127V~
8.33A @ 100V~
8.34A @120V~
7.88A @ 127V~
8.33A @ 100V~
8.34A @120V~
7.88A @ 127V~
10.8A @ 100V~
12A @ 120V~
11.34A @ 127V~
10.8A @ 100V~
12A @ 120V~
11.34A @ 127V~
P.F. = 0.6
P.F. = 0.8
P.F. = 0.8
P.F. = 0.6
P.F. = .76
P.F. = .76
Efficiency with
Nominal Load
98%
Maximum Operating
Altitude at 100% of
Nominal Power
3280 ft. (1000 m)
Online Overload
Capability
<120% 5 minutes; <150% 1 minute;
>=150% 10 seconds
Overload Capacity
in Battery Mode
<120% 10 seconds; >=120% 1 second
Current Limitation
10A
10A
15A
15A
15A
15A
Autonomy Time at
Full Load
3 minutes @ 420W
3 minutes @600W
3 minutes @ 770W
3 minutes @ 770W
2 minutes @
1100W
2 minutes @
1100W
Battery Recharge
Time
6 hours @ recharge to 90% with 50% R-load discharging
Transfer Time
6-8 milliseconds typical (<10 milliseconds max)
Outlets
4x 5-15R outlets
with battery backup,
regulation, surge
4x 5-15R outlets
with battery backup,
regulation, surge
5x 5-15R outlets
with battery backup,
regulation and
surge
4x 5-15R outlets
with battery backup,
regulation and
surge
5x 5-15R outlets
with battery backup,
regulation and
surge
5x 5-15R outlets
with battery backup,
regulation and
surge
Maximum Input
Current
6.01A
6.01A
5.69A
6.44A
6.44A
6.09A
8.59A
8.60A
8.12A
8.59A
8.60A
8.12A
10.8A
12.0A
11.34A
10.8A
12.0A
11.34A