Viking VMOR Use and Care Manual - Page 29
Charcoal Filter, Microwave, Oven Light
![]() |
View all Viking VMOR manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Cleaning and Care CHARCOAL FILTER Charcoal Filter is used for Non-vented, recirculated installation. The filter should be changed every 6 to 12 months depending on use. 1. Disconnect power to the oven at the circuit breaker panel or by unplugging. 2. Remove 2 screws that secure louver. 3. Remove louver by gently moving louver and pull away from unit. 4. Remove 2 screws that secure the sensor duct cover. 5. Remove the sensor duct cover. 6. Remove old charcoal filter (if one is installed). 7. Slide new charcoal filter into position on the support tabs. 8. Reattach sensor duct cover and secure with 2 screws. 9. Push louver back into place and replace the 2 screws to secure louver. Sensor duct cover MICROWAVE OVEN LIGHT Remove the louver per instructions 1-3 on CHARCOAL FILTER section and charcoal filter, if used. 4. Slide the light cover forward and lift up. 5. Remove old light bulb and replace only with a 20 watt bulb available at most hardware stores or lighting centers. DO NOT USE A BULB LARGER THAN 30 WATTS. 6. Replace the microwave oven light cover and charcoal filter, if used; push louver back in place and replace the louver mounting screws. Charcoal filter Oven light Screw Louver Charcoal filter Product Care 29 E
![](/manual_guide/products/viking-vmor-use-care-manual-17bce2b/29.png)