Yamaha CLP-950 Owner's Manual - Page 38
Connecting to an IBM-PC/AT Series Computer - clavinova owners manual
View all Yamaha CLP-950 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Connecting to a Personal Computer IBM-PC/AT Series Computer Set to the "PC-2" position. TO HOST Mac MIDI PC-1 PC-2 HOST SELECT CLP-930 Connecting to an IBM-PC/AT Series Computer Connect the TO HOST connector of the Clavinova to the RS-232C port on your IBM computer, using a standard 8-pin MINI DIN → 9-pin D-SUB cross cable. Set the HOST SELECT switch to the "PC-2" position. Refer to your software owner's manual for information on any settings you might have to make on the computer side. G "PC-2" Cable Connections MINI DIN 8-PIN 1 2 3 4 8 5 • 8-pin mini DIN → 9-pin D-SUB cable. • Data transfer rate: 38,400 bps. 8 (CTS) 7 (RST) 2 (RxD) 5 (GND) D-SUB 9-PIN 3 (TxD) NOTE • If your system doesn't work properly with the connections and settings listed above, your software may require different settings. Check your software operation manual and if it requires a 31,250 bps. data transfer rate, set the HOST SELECT switch to "PC-1". • When using the TO HOST terminal to connect to a personal computer using Windows, a Yamaha MIDI driver must be installed in the personal computer. The Yamaha MIDI driver can be obtained at Yamaha's home page on the World Wide Web, . G Connector Pin Numbers MINI DIN 8-PIN 6 78 34 5 12 D-SUB 9-PIN 54321 9876 38 CLP-950/930