SMG-700 configuration, Interface Configuration, PPPoE Setting Configuration
View all ZyXEL VES-1616PE-54 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
SMG-700 configuration 1. Interface Configuration a. Go to Network Setting > Interface Configuration b. Select "up1" for the uplink Interface c. Input the IP Address for the uplink interface, e.g. "172.168.23.10" d. Input the IP Subnet Mask for the uplink interface, e.g. "255.255.255.0" e. Click Apply f. Select "down1" for the downlink Interface g. Input the IP Address for the downlink interface, e.g. "172.168.23.10" h. Input the IP Subnet Mask for the downlink interface, e.g. "255.255.255.0" i. Click Apply 2. PPPoE Setting Configuration a. Go to Service Setting > PPPoE Setting b. Type the AC name (access concentrator) of the PPPoE service, e.g. "test.com" c. Select the Increment IP address and start from and input the IP, e.g. "192.168.3.100" d. Input the Maximum Concurrent Sessions, e.g. "3000" e. Check the Allow Duplicate MAC Address box f. Click Apply 20