Brother International BM-917B Instruction Manual - English - Page 12
Caution
View all Brother International BM-917B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
5-5. Ground Wire Connections 5. INSTALLATION 1974M Connect the ground wire to the sewing machine head and motor. (Use the correct type of ground wire.) 1. Secure the ground wire (1) to the sewing machine head with screw(2). (The attachment location is indicated by a ground symbol(3).) 2. Pass the ground wire (1) through the hole in the table. 3. Connect the ground wire (1) to the motor in accordance with the instructions in the instruction manual for the motor. 5-6. Lubrication CAUTION Do not connect the power cord until lubrication has been completed, otherwise the machine may operate if the pedal is pressed by mistake, which could result in injury. Be sure to wear protective goggles and gloves when handling the lubricating oil, so that no oil gets into your eyes or onto your skin, otherwise inflammation can result. Furthermore, do not drink the oil under any circumstances, as it can cause vomiting and diarrhoea. Keep the oil out of the reach of children. 1975M ! The sewing machine should always be lubricated and the oil supply replenished before it is used for the first time, and also after long periods of non-use. ! Use only the lubricating oil (Nisseki Mitsubishi Sewing Lube 10N; VG10) specified by Brother. 1. Open bed cover R (1) and bed cover L (2). 2. Add 1−2 drops of oil in the places indicated by the arrows. 1976M BM-917B, 917C 6