Brother International LK3-B434E MKII Instruction Manual - English - Page 15
Installing the operation panel, 3-12. Connecting the ground wire
View all Brother International LK3-B434E MKII manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
3. INSTALLATION 3-11. Installing the operation panel The operation panel can be installed to either the top or bottom of the work table. Top of work table e Bottom of work table q r q r w e t w Table t Table 1. Install the rear frame q to the work table (top or bottom) with the four wood screws w. 2. Install the front frame e to the rear frame q with the four screws r. * The vertical orientation of the front frame e is the same whether it is installed to the top or the bottom of the work table. 3. Insert the connector cord t into the control box through the hole at the side of the box. Refer to "3-13. Connecting the cords" for details on connecting the cord. 4. Secure the connector cord t with the staples (in three places). 3-12. Connecting the ground wire CAUTION Be sure to connect the ground. If the ground connection is not secure, you run the risk of receiving a serious electric shock, and problems with correct operation may also occur. Red White Black Yellow/Green Connect to the power switch. However, the black wire is insulated to the inside of the box and is not used. Connect to ground 9 LK3-B434E Mark II