Brother International LK3-B434E MKII Instruction Manual - English - Page 26

OPERATION, 5-1. Name and function of each operation panel item

Page 26 highlights

5. OPERATION 5-1. Name and function of each operation panel item 5. OPERATION B430E Series u q POWER P PROGRAM NO. P1 P2 i X-SCALE w o RESET Y-SCALE P3 P4 !0 SPEED r e !1 TEST COUNTER !4 t BOBBIN.WIND SELECT y q POWER indicator Illuminates when the power switch has been turned on. w RESET switch Press this switch to reset the machine when an error occurs. e TEST switch Use this switch when you want to operate only the feed mechanism in order to check a pattern. r TEST indicator Illuminates when the TEST switch has been pressed. t BOBBIN. WIND switch ......... Press this switch to wind the lower thread. y SELECT switch Use this switch to select a menu (program number, X and Y feed, speed and counter). Each time the switch is pressed, one of the menu indicators (u to !1) illuminates, and the setting for that menu item appears in the display !.4 The illiminated indicator changes as follows each time the switch is pressed. PROGRAM NO. indicator u →X-SCALE indicator i →Y-SCALE indicator o →SPEED indicator !0 →COUNTER indicator !1 u PROGRAM NO. indicator ..... Illuminates when the SELECT switch y is pressed to shown the program number setting. LK3-B434E Mark II 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

20
LK3-B434E Mark II
5. OPERATION
5-1. Name and function of each operation panel item
SELECT
PROGRAM NO.
RESET
COUNTER
X
-
SCALE
Y
-
SCALE
SPEED
P
TEST
BOBBIN.WIND
P4
P3
P1
P2
POWER
B430E
Series
q
w
r
e
t
y
u
i
o
!
0
!
1
!
4
q
POWER indicator
..................
Illuminates when the power switch has been turned on.
w
RESET switch
........................
Press this switch to reset the machine when an error occurs.
e
TEST switch
..........................
Use this switch when you want to operate only the feed mechanism in order
to check a pattern.
r
TEST indicator
......................
Illuminates when the TEST switch has been pressed.
t
BOBBIN. WIND switch
.........
Press this switch to wind the lower thread.
y
SELECT switch
......................
Use this switch to select a menu (program number, X and Y feed, speed and
counter). Each time the switch is pressed, one of the menu indicators (
u
to
!
1
) illuminates, and the setting for that menu item appears in the display
!
4
.
The illiminated indicator changes as follows each time the switch is pressed.
PROGRAM NO. indicator
u
X-SCALE indicator
i
Y-SCALE indicator
o
SPEED indicator
!
0
COUNTER indicator
!
1
u
PROGRAM NO. indicator
.....
Illuminates when the SELECT switch
y
is pressed to shown the program
number setting.
5. OPERATION