Brother International LK3-B434E MKII Instruction Manual - English - Page 67

TABLE OF ERROR CODES, REFERENCE, segment LED alphabet

Page 67 highlights

15. TABLE OF ERROR CODES Code E-80 E-81 E-82 E-90 E-91 E-A0 E-b0 E-b1 E-d0 E-E0 E-E1 E-E2 Cause Motor PROM is not correctly inserted. Foot switch was depressed when the power was turned on. Remedy Turn off the power and check. Turn off the power and check. An operation panel switch was depressed Turn off the power and check the operation panel. when the power was turned on. Check that all panel cords are normal. Abnormal drop in power supply voltage, or power was turned on again immediately after it was turned off. Turn off the power and check the input voltage. After turning off the power, wait 3 seconds or more before turning it on again. (Refer to "10-13. Checking the input voltage".) Abnormal rise in power supply voltage. Turn off the power and check the input voltage. (Refer to "10-13. Checking the input voltage".) Home position cannot be detected (malfunction of home position sensor), or malfunction of power supply circuit board. Turn off the power and check the connection of home position sensor connector P1. You tried to change the program number Press the RESET switch. Set DIP switch A-8 to OFF when DIP switch A-8 was set to ON. before trying to change the program number. No sewing data available. Replace the PROM with one which contains sewing data. Heat sink of control circuit board is abnormally hot. Turn off the power and clean the air intake port of the box. Malfunction of EEPROM (malfunction of main circuit board). Turn off the power, and turn it back on. If the error continually occurs, contact a qualified service technician. Corrupted EEPROM data, or main PROM version has been upgraded. Press the RESET switch to reset the error. However, the data (memory switches, display and user programs) will be reset to the backup data or initialized. Corrupted EEPROM control information data. Press the RESET switch to reset the error. However, the data (memory switches, display and user programs) will all be initialized. E-F0 E-F1 E-F2 Solenoid short-circuit (malfunction of main circuit board), or power relay is not operating (malfunction of power supply circuit board). Turn off the power and contact a qualified service technician. Bad connection in cable between power Turn off the power and check if connectors P16 is supply circuit board and main circuit board. disconnected. Abnormal current detected in power supply circuit board. Turn off the power and contact a qualified service technician. s Errors generated when optional equipment is connected Code Cause Remedy E-14 Thread breakage detected. Turn the EMERGENCY STOP switch clockwise to release the lock, and then press the RESET switch to reset the error. You can then press the BOBBIN. WIND switch to repeat the sewing. E-15 Air pressure drop error. Turn off the power and check. If drops in air pressure are not being detected, clear all memory settings and then set the memo-1d switch to OFF. E-16 Bobbin thread sensor mechanism error Turn off the power and check. If the bobbin thread amount is not being detected, clear all memory settings and then set the memo-24 switch to OFF. REFERENCE segment LED alphabet Panel display Text display A b c d E F 6 H L o 61 LK3-B434E Mark II

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

61
LK3-B434E Mark II
15. TABLE OF ERROR CODES
E-80
E-81
E-82
E-90
E-91
Cause
Motor PROM is not correctly inserted.
Foot switch was depressed when the
power was turned on.
An operation panel switch was depressed
when the power was turned on.
Abnormal drop in power supply voltage,
or power was turned on again
immediately after it was turned off.
Abnormal rise in power supply voltage.
Remedy
Turn off the power and check.
Turn off the power and check.
Turn off the power and check the operation panel.
Check that all panel cords are normal.
Turn off the power and check the input voltage. After turning
off the power, wait 3 seconds or more before turning it on
again. (Refer to
10-13. Checking the input voltage
.)
Turn off the power and check the input voltage.
(Refer to
10-13. Checking the input voltage
.)
Code
E-E2
Corrupted EEPROM control information
data.
Press the RESET switch to reset the error. However,
the data (memory switches, display and user
programs) will all be initialized.
E-A0
E-b1
Replace the PROM with one which contains sewing
data.
No sewing data available.
E-b0
E-d0
E-E0
E-F0
E-F1
E-F2
E-E1
Home position cannot be detected
(malfunction of home position sensor), or
malfunction of power supply circuit board.
You tried to change the program number
when DIP switch A-8 was set to ON.
Heat sink of control circuit board is abnormally hot.
Malfunction of EEPROM (malfunction of
main circuit board).
Solenoid short-circuit (malfunction of main
circuit board), or power relay is not operating
(malfunction of power supply circuit board).
Bad connection in cable between power
supply circuit board and main circuit board.
Abnormal current detected in power
supply circuit board.
Corrupted EEPROM data, or main PROM
version has been upgraded.
Turn off the power and check the connection of
home position sensor connector P1.
Press the RESET switch. Set DIP switch A-8 to OFF
before trying to change the program number.
Turn off the power and clean the air intake port of the box.
Turn off the power, and turn it back on. If the error
continually occurs, contact a qualified service technician.
Turn off the power and contact a qualified service
technician.
Turn off the power and check if connectors P16 is
disconnected.
Turn off the power and contact a qualified service
technician.
Press the RESET switch to reset the error. However, the
data (memory switches, display and user programs)
will be reset to the backup data or initialized.
E-14
E-15
E-16
Cause
Thread breakage detected.
Air pressure drop error.
Bobbin thread sensor mechanism error
Remedy
Turn the EMERGENCY STOP switch clockwise to
release the lock, and then press the RESET switch
to reset the error. You can then press the BOBBIN.
WIND switch to repeat the sewing.
Turn off the power and check. If drops in air
pressure are not being detected, clear all memory
settings and then set the memo-1d switch to OFF.
Turn off the power and check. If the bobbin thread
amount is not being detected, clear all memory
settings and then set the memo-24 switch to OFF.
Code
Panel display
Text display
A
b
c
d
E
F
6
H
L
o
Errors generated when optional equipment is connected
REFERENCE
segment LED alphabet