Brother International LK3-B434E MKII Instruction Manual - English - Page 52

Adjustment of air pressure (for pneumatic), 10-17. Adjustment of inner clamping device

Page 52 highlights

10. STANDARD ADJUSTMENTS 10-16. Adjustment of air pressure (for pneumatic) Increase pressure y Increase pressure w q t u r 1. Air pressure should be 0.5 Mpa. The air pressure can be adjusted by pulling up and turning the control knob w on the integrator q. After adjustment is complete, push the control knob w downward to lock it. 2. Adjust the air pressure for the reversal cylinder to stay within such a range that the presser crank r rotates reversely when pressing the sewing material with the pressure plate e. (Approx. 0.3 Mpa) For adjustment, pull up and, turn the control knob y on the air regulator t. After adjustment is complete, push the control knob y downward to lock it. 3. If water stands in the bottle of the integrator q, turn the drain cock u in the direction indicated by an arrow to drain the water. e 10-17. Adjustment of inner clamping device w r t q (B)" e s Adjustment of the positioning plates Loosen the screws w, and adjust the position of the positioning plate R e so that the label q can be evenly laid out between the front and back seams (A). Next, loosen the screws r, and adjust the position of the positioning plate L t so that the presser plate can be evenly laid out between the left and right seams (B). "(A) (B)" "(A) s Adjustment of the presser crank horizontal position q Loosen the nut e and push in or pull out the ad- justing bolt r so that the presser crank w can be horizontal when the reversal cylinder plunger q is moved to the left extreme. e w r LK3-B434E Mark II 46

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

46
LK3-B434E Mark II
10-16. Adjustment of air pressure (for pneumatic)
1.
Air pressure should be 0.5 Mpa.
The air pressure can be adjusted by pulling up and
turning the control knob
w
on the integrator
q
.
After adjustment is complete, push the control
knob
w
downward to lock it.
2.
Adjust the air pressure for the reversal cylinder to
stay within such a range that the presser crank
r
rotates reversely when pressing the sewing mate-
rial with the pressure plate
e
. (Approx. 0.3 Mpa)
For adjustment, pull up and, turn the control knob
y
on the air regulator
t
.
After adjustment is complete, push the control
knob
y
downward to lock it.
3.
If water stands in the bottle of the integrator
q
,
turn the drain cock
u
in the direction indicated by
an arrow to drain the water.
Adjustment of the positioning plates
Loosen the screws
w
, and adjust the position of the
positioning plate R
e
so that the label
q
can be
evenly laid out between the front and back seams
(A).
Next, loosen the screws
r
, and adjust the position
of the positioning plate L
t
so that the presser plate
can be evenly laid out between the left and right
seams (B).
10-17. Adjustment of inner clamping device
Adjustment of the presser crank horizontal position
Loosen the nut
e
and push in or pull out the ad-
justing bolt
r
so that the presser crank
w
can be
horizontal when the reversal cylinder plunger
q
is
moved to the left extreme.
Increase pressure
Increase pressure
(B)
(B)
(A)
(A)
10. STANDARD ADJUSTMENTS
t
y
w
q
u
r
e
t
r
w
q
e
w
r
e
q