Canon CanoScan FB 1200S Product Guide - Page 23

when the switch is set to the upper side, and On when it is to the lower side., To set the SCSI ID

Page 23 highlights

To set the SCSI ID, move the 1-3 switches with a sharp object, such as the tip of a mechanical pencil. Set the switch positions as below to assign a SCSI ID from 0 to 6. Set the SCSI ID with switches 1-3 indicates the switch position Set the switch to this side to turn it Off Set the switch to this side to turn it On SCSI ID 0 SCSI ID 1 SCSI ID 2 SCSI ID 3 SCSI ID 4 SCSI ID 5 SCSI ID 6 To set the terminator ID, move the switch labeled 4. As shown below, the terminator is Off when the switch is set to the upper side, and On when it is to the lower side. The SCSI ID is set to 2 and the terminator is On when this equipment is shipped from the factory. Terminator Off Terminator On SCSI ID = 2 Fourth switch is set to the upper side Fourth switch is set to the lower side Terminator On (Default factory setting) 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107

23
To set the SCSI ID, move the 1-3 switches with a sharp object, such as the tip of a
mechanical pencil. Set the switch positions as below to assign a SCSI ID from 0 to 6.
To set the terminator ID, move the switch labeled 4. As shown below, the terminator is Off
when the switch is set to the upper side, and On when it is to the lower side.
The SCSI ID is set to 2 and the terminator is On when this equipment is shipped from the factory.
Set the SCSI ID with switches 1-3
indicates the switch position
SCSI ID 0
SCSI ID 1
SCSI ID 2
SCSI ID 3
SCSI ID 4
SCSI ID 5
SCSI ID 6
Set the switch to this side to turn it Off
Set the switch to this side to turn it On
Terminator Off
Terminator On
Fourth switch is set to
the upper side
Fourth switch is set to
the lower side
(Default factory setting)
Terminator On
SCSI ID = 2