Page 44 highlights

Installation Summary Chapter 2 Installation Overview • For outdoor installations, connect the dual-coax Ethernet cables between the power injector and the grounding block. For indoor installations, connect the dual-coax cables to the power injector. Tip You can connect the dual-coax cable connectors to either of the grounding block connectors or the power injector's dual-coax Ethernet ports. The access point/bridge senses the Ethernet signals and automatically switches internal circuitry to match the cable connections. Note You should securely tighten the cable connectors (15 to 20 inch-pounds) using a small wrench. • For outdoor installations, connect a ground wire to the grounding block. • Mount the access point/bridge to the mast, tower, or wall. For additional information, refer to the mounting instructions that shipped with your access point/bridge. Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024 • Connect a ground wire to the access point/bridge (use the ground lug). • For outdoor installations, connect the dual-coax Ethernet cables to the grounding block and to the access point/bridge. For indoor installations, connect the dual-coax cables directly to the access point/bridge. Tip You can connect the dual-coax cable connectors to either of the grounding block connectors or the access point/bridge's dual-coax ports. The access point/bridge senses the Ethernet signals and automatically switches internal circuitry to match the cable connections. Note You should securely tighten the cable connectors (15 to 20 inch-pounds) using a small wrench. Warning This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 20A Statement 1005 • For indoor installations, connect these items: - The AC power cord to the 48-VDC power module. - The power module power plug to the power injector and plug the AC cord into an AC power receptacle. • For outdoor installations, refer to the mounting instruction document that shipped with your access point/bridge. • Seal all external connectors with special weather sealing material. Configure security and other access point/bridge options. For additional information, refer to the Cisco IOS Software Configuration Guide for Access Points or the Cisco Wireless LAN Controller Configuration Guide. 2-10 Cisco Aironet 1300 Series Wireless Outdoor Access Point/Bridge Hardware Installation Guide OL-5048-06

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

2-10
Cisco Aironet 1300 Series Wireless Outdoor Access Point/Bridge Hardware Installation Guide
OL-5048-06
Chapter 2
Installation Overview
Installation Summary
For outdoor installations, connect the dual-coax Ethernet cables between the power injector and the
grounding block. For indoor installations, connect the dual-coax cables to the power injector.
Tip
You can connect the dual-coax cable connectors to either of the grounding block connectors or
the power injector’s dual-coax Ethernet ports. The access point/bridge senses the Ethernet
signals and automatically switches internal circuitry to match the cable connections.
Note
You should securely tighten the cable connectors (15 to 20 inch-pounds) using a small wrench.
For outdoor installations, connect a ground wire to the grounding block.
Mount the access point/bridge to the mast, tower, or wall. For additional information, refer to the
mounting instructions that shipped with your access point/bridge.
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection
authority or an electrician if you are uncertain that suitable grounding is available.
Statement 1024
Connect a ground wire to the access point/bridge (use the ground lug).
For outdoor installations, connect the dual-coax Ethernet cables to the grounding block and to the
access point/bridge. For indoor installations, connect the dual-coax cables directly to the access
point/bridge.
Tip
You can connect the dual-coax cable connectors to either of the grounding block connectors or
the access point/bridge’s dual-coax ports. The access point/bridge senses the Ethernet signals
and automatically switches internal circuitry to match the cable connections.
Note
You should securely tighten the cable connectors (15 to 20 inch-pounds) using a small wrench.
Warning
This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that
the protective device is rated not greater than: 20A
Statement 1005
For indoor installations, connect these items:
The AC power cord to the 48-VDC power module.
The power module power plug to the power injector and plug the AC cord into an AC power
receptacle.
For outdoor installations, refer to the mounting instruction document that shipped with your access
point/bridge.
Seal all external connectors with special weather sealing material.
Configure security and other access point/bridge options. For additional information, refer to the
Cisco
IOS Software Configuration Guide for Access Points
or the
Cisco Wireless LAN Controller
Configuration Guide
.