D-Link DXS-3600-EM-STACK Hardware Installation Guide - Page 31

LED Indicators, Port Specifications, Per Device, Power1, Management, Console, Fan 1, Stacking ID

Page 31 highlights

DXS-3600 Series 10GbE Layer 2/3 Switch Hardware Installation Guide Port Specifications SFP+ Direct Attached Cables (DAC): • Direct Attached Cables are cables with a built-in SFP+ transceivers at both ends. • DEM-CB100S (10GbE SFP+ 1m Direct Attach Cable) • DEM-CB300S (10GbE SFP+ 3m Direct Attach Cable) • DEM-CB700S (10GbE SFP+ 7m Direct Attach Cable) LED Indicators Location Per Device LED Power1, Power 2 Color Green Amber Management (MGMT) Green Console Green Fan 1, Fan 2, Fan 3 Green Amber SD Green Stacking ID (7-segment LED) Red Green Status Light on (Solid) Light off Light on (Solid) Light blinking Light on (Solid) Light blinking Light off Light on (Solid) Light off Light on (Solid) Light off Light on (Solid) Light blinking Light on (Solid) Light blinking Light off Light on (Solid) Light on (1-12) Light on (H) Light on (h) Light on (E) Light on (G) Description Power on Power off Power supply failure Power supply module present, but AC or DC input is problematic. A reversed airflow power supply was inserted. Link present. No data transmission. Activity. Data transmission. No link present or the port was shutdown. Console on Console off Diagnostics pass. Functioning normal. No power. Busy booting or running diagnostics. Fan failure or reversed airflow fan was inserted. SD plugged in. Busy reading/writing. No link. Read/Write failure. Stacking number displayed. Stacking Master Stacking Backup Master System self-test error Safeguard Engine in exhausted mode 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

DXS-3600 Series 10GbE Layer 2/3 Switch Hardware Installation Guide
25
SFP+ Direct Attached Cables (DAC):
• Direct Attached Cables are cables with a built-in SFP+ transceivers at both ends.
• DEM-CB100S (10GbE SFP+ 1m Direct Attach Cable)
• DEM-CB300S (10GbE SFP+ 3m Direct Attach Cable)
• DEM-CB700S (10GbE SFP+ 7m Direct Attach Cable)
LED Indicators
Location
LED
Color
Status
Description
Per Device
Power1, Power 2
Green
Light on (Solid)
Power on
Light off
Power off
Amber
Light on (Solid)
Power supply failure
Light blinking
Power supply module
present, but AC or DC input is
problematic.
A reversed airflow power
supply was inserted.
Management
(MGMT)
Green
Light on (Solid)
Link present. No data
transmission.
Light blinking
Activity. Data transmission.
Light off
No link present or the port
was shutdown.
Console
Green
Light on (Solid)
Console on
Light off
Console off
Fan 1, Fan 2, Fan 3
Green
Light on (Solid)
Diagnostics pass. Functioning
normal.
Light off
No power.
Amber
Light on (Solid)
Busy booting or running
diagnostics.
Light blinking
Fan failure or reversed airflow
fan was inserted.
SD
Green
Light on (Solid)
SD plugged in.
Light blinking
Busy reading/writing.
Light off
No link.
Red
Light on (Solid)
Read/Write failure.
Stacking ID
(7-segment LED)
Green
Light on (1-12)
Stacking number displayed.
Light on (H)
Stacking Master
Light on (h)
Stacking Backup Master
Light on (E)
System self-test error
Light on (G)
Safeguard Engine in
exhausted mode
Port Specifications