Dell PowerEdge 2300 User's Guide - Page 103

x 6 hot-pluggable SCSI backplane board, x 3 non-hot-pluggable SCSI backplane board, x 2 non-hot-

Page 103 highlights

The SCSI drive must be configured as follows: Disable termination on the drive. The SCSI backplane board provides termination for the SCSI bus. Set the SCSI ID on all drives to 0. All SCSI ID numbers for the drives are set by the SCSI backplane board, as shown in Figure 7-2. Configure the drive so that the drive motor waits for a Start Unit command from the SCSI host adapter before spinning. SCSI ID 5 SCSI ID 0 1 x 6 hot-pluggable SCSI backplane board SCSI ID 5 SCSI ID 0 2 x 3 non-hot-pluggable SCSI backplane board SCSI ID 3 SCSI ID 0 2 x 2 non-hot-pluggable SCSI backplane board Installing SCSI Hard-Disk Drives 7-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170

Installing SCSI Hard-Disk Drives
7-3
6&6,±+DUG¶’LVN±’ULYH±&RQILJXUDWLRQ
The SCSI drive must be configured as follows:
²
Disable termination on the drive. The SCSI backplane board provides termination
for the SCSI bus.
²
Set the SCSI ID on all drives to 0. All SCSI ID numbers for the drives are set by
the SCSI backplane board, as shown in Figure 7-2.
²
Configure the drive so that the drive motor waits for a Start Unit command from
the SCSI host adapter before spinning.
)LJXUH±¼¶·µ±±6&6,±+DUG¶’LVN±’ULYH±,’±1XPEHULQJ
1 x 6 hot-pluggable SCSI backplane board
2 x 3 non–hot-pluggable SCSI backplane board
2 x 2 non–hot-pluggable SCSI backplane board
SCSI ID 0
SCSI ID 5
SCSI ID 0
SCSI ID 5
SCSI ID 0
SCSI ID 3