EMC CX600 Configuration Guide - Page 106

IP Remote Mirror Dual IP - Fabric Servers CX400, CX600, FC4700

Page 106 highlights

February 3, 2003 EMC CLARiiON Open Systems Configuration Guide 12. IP Remote Mirror Dual IP - Fabric Servers (CX400, CX600, FC4700) NT NT H H B B A A H H B B A A RED = Dedicated to mirroring Solaris H H B B A A Solaris H H B B A A FC Switches FC Switches FC Switch FC Switch FC-to-IP Device FC-to-IP Device IP Network 01 SP A 01 SP B LUN LUN LUN LUN LUN LUN LUN Site 1 - CX400 or FC4700 NT Cluster Storage Group Primary Mirror Images Database Server Storage Group Primary Mirror Images Mail Server Storage Group Secondary MIrror Images FC-to-IP Device FC Switches FC Switches FC-to-IP Device FC Switch FC Switch 01 SP A 01 SP B NT Cluster Storage Group Secondary MIrror Images Database Server Storage Group Secondary Mirror Images Mail Server Storage Group Primary Mirror Images LUN LUN LUN LUN LUN LUN LUN Site 2 - CX400 or FC4700 NOTE: See General Configuration Rules (page 6), Failover Configuration Rules (page 15), and Switch Topology Rules (page 20). Document Rev 19 Page 106 EMC Confidential

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149

February 3, 2003
EMC CLARiiON Open Systems Configuration Guide
Document Rev
19
Page 106
EMC Confidential
12. IP Remote Mirror Dual IP - Fabric Servers (CX400, CX600, FC4700)
NT
H
B
A
H
B
A
Solaris
H
B
A
H
B
A
NT
H
B
A
H
B
A
Solaris
H
B
A
H
B
A
NT Cluster Storage Group
Primary Mirror Images
Database Server Storage Group
Primary Mirror Images
Mail Server Storage Group
Secondary MIrror Images
Mail Server Storage Group
Primary Mirror Images
NT Cluster
Storage Group
Secondary MIrror Images
Site 1 - CX400 or FC4700
Site 2 - CX400 or FC4700
FC Switches
Database Server Storage Group
Secondary Mirror Images
FC Switches
FC Switches
LUN
LUN
LUN
LUN
LUN
LUN
LUN
SP A
0
1
SP B
0
1
LUN
LUN
LUN
LUN
LUN
LUN
LUN
SP A
0
1
SP B
0
1
FC-to-IP
Device
RED
= Dedicated to mirroring
FC Switch
FC Switch
FC Switch
FC Switch
IP Network
FC Switches
FC-to-IP
Device
FC-to-IP
Device
FC-to-IP
Device
NOTE
: See
General Configuration Rules
(page 6),
Failover Configuration Rules
(page 15)
,
and
Switch Topology Rules
(page 20).