EMC CX600 Configuration Guide - Page 122

Switch Zone Number, Participants in Zone by WWPN, Server

Page 122 highlights

February 3, 2003 EMC CLARiiON Open Systems Configuration Guide Example 2 Single-Initiator Zoning with Dual HBA-Port and Single HBA-Port Servers Connected to a CX400 or FC4700 Server A with PowerPath NT Server B with DMP Solaris Server C CDE 2000 H H H H H B B B B B A A A A A 0 1 2 3 4 FC Fabric FC Fabric 01 SP0 01 SP1 LUN LUN LUN LUN LUN LUN LUN CX400 or FC4700 Configuration Goals • Connect both ports of SPs so different servers can use the SP front end ports. • Cross port 1 on each SP to the other fabric so the configuration is ready for future use of multi-path PowerPath, alternate-path DMP, or multi-path ATF. • Use switch zoning to ensure that each server can see only one path to an SP. Zone Contents Switch Zone Number 1 2 3 4 5 Participants in Zone by WWPN HBA0, SPA0 HBA1, SPB0 HBA2, SPB1 HBA3, SPA1 HBA4, SPA1, SPB0 Server Server A has a Storage Group on the CX400 or FC4700 Server B has a Storage Group on the CX400 or FC4700 Server C has a Storage Group on the CX400 or FC4700 Document Rev 19 Page 122 EMC Confidential

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149

February 3, 2003
EMC CLARiiON Open Systems Configuration Guide
Document Rev
19
Page 122
EMC Confidential
Example 2
Single-Initiator Zoning with Dual HBA-Port and Single HBA-Port Servers Connected to a CX400 or FC4700
Configuration Goals
Connect both ports of SPs so different servers can use the SP front end ports.
Cross port 1 on each SP to the other fabric so the configuration is ready for future use of multi-path PowerPath, alternate-path
DMP, or multi-path ATF.
Use switch zoning to ensure that each server can see only one path to an SP.
Zone Contents
Switch Zone Number
Participants in Zone by WWPN
Server
1
HBA0
,
SPA0
Server A has a Storage Group on the CX400 or
FC4700
2
HBA1
,
SPB0
3
HBA2
,
SPB1
Server B has a Storage Group on the CX400 or
FC4700
4
HBA3
,
SPA1
5
HBA4
,
SPA1, SPB0
Server C has a Storage Group on the CX400 or
FC4700
NT
H
B
A
0
H
B
A
1
Solaris
H
B
A
2
H
B
A
3
Server A
with PowerPath
2000
H
B
A
4
FC Fabric
Server B
with DMP
Server C
CDE
FC Fabric
CX400 or FC4700
LUN
LUN
LUN
LUN
LUN
LUN
LUN
SP0
0
1
SP1
0
1