EMC CX600 Configuration Guide - Page 47

Linux Single Fabric Connections

Page 47 highlights

February 3, 2003 EMC CLARiiON Open Systems Configuration Guide Linux Single Fabric Connections See General Configuration Rules (page 6) and Switch Topology Rules (page 20). Servers: Multiple with same or different operating systems. See Fan-Out Rule (page 9), Clustered Server Configuration Rules (page 14). Storage Systems: Multiple CX200, CX400, CX600, FC4500, FC4700, or FC5300 (FC5300 configuration available from selected channels; MIA required optical connect). See Fan-In Rule (page 9). For the failover software supported for a storage system, see Failover Configuration Rules (page 15). Fabric: See Storage Area Network (SAN) Configuration Rules (page 9), Port Speed Rules (page 14), and General Switch Topology Rules (page 20). Configurations: Storage Systems CX200 CX400 CX600 FC4500 FC4700 FC5300 Servers Single CX200 CX400 CX600 FC4700 CX200 CX400 CX600 FC4500 FC4700 FC5300 Multiple Multiple CX400 CX600 FC4700 Multiple CX200 CX400 CX600 FC4500 FC4700 FC5300 Multiple HBA Ports per Server Multiple Multiple 1 1 PowerPath - multiple PowerPath Base 1 or 2 Utility Kit PowerPath -1 Ports Used per SP PowerPath - multiple except for 1 for CX200, FC4500 PowerPath Base - 1 FC5300 - 1 1 1 PowerPath - multiple Utility Kit PowerPath - 1 PowerPath - multiple except 1 for CX200, FC4500, and FC5300 PowerPath Base, Utility Kit PowerPath - 1 Requirements/Comments PowerPath, PowerPath Base except for FC5300. No SP failover for FC5300. Optional multiple paths from server to each SP (except for FC5300). Clusters not applicable. Access Logix required for CX200, FC4500, FC5300, and optional SnapView (CX600, FC4700). No SP failover. Clusters required. Access Logix required for optional SnapView (CX400, CX600, FC4700) and optional MirrorView (CX400, CX600, FC4700). PowerPath, PowerPath Base, Utility Kit PowerPath except for FC5300 or clustered server. No SP failover for FC5300 or clustered server. No non-disruptive software installation (NDU) for clustered server. Clusters optional for - Oracle9iRAC. Access Logix, optional SnapView (CX400, CX600, FC4700), optional MirrorView (CX400, CX600, FC4700). PowerPath or Utility Kit PowerPath except for a clustered server. No SP failover or non-disruptive software installation (NDU) for clustered server. Clusters optional - Oracle9iRAC. No Access Logix, no SnapView, optional MirrorView. PowerPath, PowerPath Base, or Utility Kit PowerPath except for FC5300 or clustered server. No SP failover for FC5300 or clustered server. No non-disruptive software installation (NDU) with clustered server. Clusters optional - Oracle9iRAC. Access Logix, optional SnapView (CX400, CX600, FC4700), optional MirrorView (CX400, CX600, FC4700). Diagrams 1 on page 89 2 on page 90 3 on page 91 4 on page 92 5 on page 93 Document Rev 19 Page 47 EMC Confidential

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149

February 3, 2003
EMC CLARiiON Open Systems Configuration Guide
Document Rev
19
Page 47
EMC Confidential
Linux Single Fabric Connections
See
General Configuration Rules
(page 6) and
Switch Topology Rules
(page 20).
Servers:
Multiple with same or different operating systems.
See
Fan-Out Rule
(page 9),
Clustered Server Configuration Rules
(page 14).
Storage Systems:
Multiple CX200, CX400, CX600, FC4500, FC4700, or FC5300 (FC5300 configuration
available from selected channels; MIA required optical connect).
See
Fan-In Rule
(page 9). For the failover software supported for a storage system, see
Failover Configuration Rules
(page 15).
Fabric:
See
Storage Area Network (SAN) Configuration Rules
(page 9),
Port Speed Rules
(page 14), and
General Switch Topology Rules
(page 20).
Configurations:
Storage
Systems
Servers
HBA Ports
per Server
Ports Used
per SP
Requirements/Comments
Diagrams
CX200
CX400
CX600
FC4500
FC4700
FC5300
Single
Multiple
PowerPath - multiple
except for 1 for CX200,
FC4500
PowerPath Base - 1
FC5300 - 1
PowerPath, PowerPath Base except for FC5300.
No SP failover for FC5300.
Optional multiple paths from server to each SP
(except for FC5300).
Clusters not applicable.
Access Logix required for CX200, FC4500,
FC5300, and optional SnapView (CX600, FC4700).
1 on page 89
CX200
CX400
CX600
FC4700
Multiple
Multiple
1
No SP failover.
Clusters required.
Access Logix required for optional SnapView
(CX400, CX600, FC4700)
and optional
MirrorView (CX400, CX600, FC4700)
.
2 on page 90
CX200
CX400
CX600
FC4500
FC4700
FC5300
Multiple
1
1
PowerPath, PowerPath Base, Utility Kit PowerPath
except for FC5300 or clustered server.
No SP failover for FC5300 or clustered server.
No non-disruptive software installation (NDU) for
clustered server.
Clusters optional for - Oracle9iRAC.
Access Logix, optional SnapView (CX400, CX600,
FC4700),
optional MirrorView (CX400, CX600,
FC4700)
.
3 on page 91
CX400
CX600
FC4700
Multiple
1
PowerPath - multiple
Utility Kit PowerPath - 1
PowerPath or Utility Kit PowerPath except for a
clustered server.
No SP failover or non-disruptive software
installation (NDU) for clustered server.
Clusters optional - Oracle9iRAC.
No Access Logix, no SnapView, optional
MirrorView.
4 on page 92
CX200
CX400
CX600
FC4500
FC4700
FC5300
Multiple
PowerPath - multiple
PowerPath Base 1 or 2
Utility Kit PowerPath -1
PowerPath - multiple
except 1 for CX200,
FC4500, and FC5300
PowerPath Base, Utility
Kit PowerPath - 1
PowerPath, PowerPath Base, or Utility Kit
PowerPath except for FC5300 or clustered server.
No SP failover for FC5300 or clustered server.
No non-disruptive software installation (NDU) with
clustered server.
Clusters optional - Oracle9iRAC.
Access Logix, optional SnapView (CX400, CX600,
FC4700), optional MirrorView (CX400, CX600,
FC4700).
5 on page 93