EMC CX600 Configuration Guide - Page 147

EMC CLARiiON Open Systems Configuration Guide, Document Rev, EMC Confidential - updates

Page 147 highlights

February 3, 2003 EMC CLARiiON Open Systems Configuration Guide Revision 10 Effective Date April 15, 2002 9 February 8, 2002 Changes Removes support for multi-path NetWare from the Path Rules (page 9), the NetWare Configuration tables, and the configuration drawings. Increases the number of paths supported for Tru64 UNIX native failover software in Path Rules (page 9). Adds support for Tru64 UNIX servers for the following to the General Configuration Rules, the Tru64 UNIX Configurations section (pages 44 and 46), and the configuration drawings: Clusters with Tru64Cluster Non-disruptive software installation (NDU) and SP failover with native Tru64 UNIX failover SnapView and MirrorView. Adds support for multiple SnapView sessions and the following sections to the SnapView Configuration Rules (page 12): Snapshot Cache LUNs Snapshot LUNs Snapshot Sessions Adds the Mirror Images section (page 14) to the MirrorView Configuration Rules (page 14). Adds a zoning information for a remote mirror configuration to the MirrorView Configuration Rules (page 14) and the Remote Mirror Zoning (page 77). Adds support for host I/O over SP port 1 in the MirrorView Configuration Rules (page 14), the remote mirror configuration drawings 8 through 12, and example 1 of switch zoning (page 78). Adds support for two secondary mirror images per primary image in the MirrorView Configuration Rules (page 14) and the configuration 9, Dual Fabric Remote Mirror (one primary image, one or more secondary images) - Fabric Servers (FC4700.) Adds support for primary mirror images on four different FC4700s and secondaries on a fifth FC4700 in the MirrorView Configuration Rules (page 14) and the new configuration drawing Multiple Fabric Remote Mirror (primary images on multiple FC4700s, secondary images on one FC4700). Clarifies Access Logix as an option for an FC4700 in a SAN by adding a new configuration for clustered server connections through a single switch to an FC4700 (Figure 1 on page 55). Changes HBA to HBA port where applicable to support future qualification of multi-port HBAs. Adds a restriction for the number of paths to an SP supported for NetWare multi-path access (Path Rules table on page 9). Clarifies that Access Logix is supported on FC4500 and FC5300 storage systems in a storage area network (SAN) only (pAGE 12). Clarifies the use of clustered servers in SnapView configurations, and adds a drawing of a Windows cluster in a SnapView configuration with tape backup (page 13). Updates the information in the Switch Zoning section (page 72) for multi-path and alternate path access from a server to a storage-system SP. Document Rev 19 Page 147 EMC Confidential

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149

February 3, 2003
EMC CLARiiON Open Systems Configuration Guide
Document Rev
19
Page 147
EMC Confidential
Revision
Effective Date
Changes
10
April 15, 2002
Removes support for multi-path NetWare from the Path Rules (page 9), the NetWare Configuration tables, and the
configuration drawings.
Increases the number of paths supported for Tru64 UNIX native failover software in Path Rules (page 9).
Adds support for Tru64 UNIX servers for the following to the General Configuration Rules, the Tru64 UNIX
Configurations section (pages 44 and 46), and the configuration drawings:
Clusters with Tru64Cluster
Non-disruptive software installation (NDU) and SP failover with native Tru64 UNIX failover
SnapView and MirrorView.
Adds support for multiple SnapView sessions and the following sections to the SnapView Configuration Rules
(page 12):
Snapshot Cache LUNs
Snapshot LUNs
Snapshot Sessions
Adds the Mirror Images section (page 14) to the MirrorView Configuration Rules (page 14).
Adds a zoning information for a remote mirror configuration to the MirrorView Configuration Rules (page 14) and
the Remote Mirror Zoning (page 77).
Adds support for host I/O over SP port 1 in the MirrorView Configuration Rules (page 14), the remote mirror
configuration drawings 8 through 12, and example 1 of switch zoning (page 78).
Adds support for two secondary mirror images per primary image in the MirrorView Configuration Rules (page 14)
and the configuration 9, Dual Fabric Remote Mirror (one primary image, one or more secondary images) - Fabric
Servers (FC4700.)
Adds support for primary mirror images on four different FC4700s and secondaries on a fifth FC4700 in the
MirrorView Configuration Rules (page 14) and the new configuration drawing Multiple Fabric Remote Mirror
(primary images on multiple FC4700s, secondary images on one FC4700).
Clarifies Access Logix as an option for an FC4700 in a SAN by adding a new configuration for clustered server
connections through a single switch to an FC4700 (Figure 1 on page 55).
9
February 8, 2002
Changes HBA to HBA port where applicable to support future qualification of multi-port HBAs.
Adds a restriction for the number of paths to an SP supported for NetWare multi-path access (Path Rules table on
page 9).
Clarifies that Access Logix is supported on FC4500 and FC5300 storage systems in a storage area network (SAN)
only (pAGE 12).
Clarifies the use of clustered servers in SnapView configurations, and adds a drawing of a Windows cluster in a
SnapView configuration with tape backup (page 13).
Updates the information in the Switch Zoning section (page 72) for multi-path and alternate path access from a
server to a storage-system SP.