EMC CX600 Configuration Guide - Page 86

Windows NT Direct Connections

Page 86 highlights

February 3, 2003 EMC CLARiiON Open Systems Configuration Guide Windows NT Direct Connections See General Configuration Rules (page 6). Servers: 1 to 4 depending on configuration. See Paths from a Server to an SP (page 10), Clustered Server Configuration Rules (page 14), Failover Configuration Rules (page 15). Storage Systems: 1 CX200, CX400, CX600, FC4500, FC4700, FC5300, or FC5700. For the failover software supported for a storage system, see Failover Configuration Rules (page 15). Configurations: Storage Systems CX200 CX400 CX600 FC4500 FC4700 FC5300 FC5700 Servers 1 CX400 1 CX600 FC4700 CX200 2 CX400 CX600 FC4500 FC4700 FC5300 FC5700 CX200 2 CX400 CX600 FC4500 FC4700 FC5300 HBA Ports per Server 1 2 Multiple 1 2 CX400 Multiple 1 CX600 FC4700 Ports Used per SP 1 1 Multiple 1 Requirements/Comments No PowerPath, Utility Kit PowerPath, ATF, or CDE. No non-disruptive software installation (NDU). Clusters not applicable. No Access Logix, no SnapView, no MirrorView. PowerPath or ATF. Clusters not applicable. No Access Logix, no SnapView, no MirrorView. PowerPath or ATF. Clusters not applicable. No Access Logix, no SnapView, no MirrorView. No PowerPath, Utility Kit PowerPath, ATF, or CDE. No non-disruptive software installation (NDU). Clusters not supported. No Access Logix, no SnapView, no MirrorView. Diagrams None 15 on page 111 16 on page 112 17 on page 113 2 Multiple PowerPath or ATF. Clusters required for storage system without Access Logix; optional for storage system with Access Logix Microsoft Cluster Server. No Access Logix (CX200, FC4500, FC5300), optional Access Logix (CX400, CX600, FC4700), optional SnapView (CX400, CX600, FC47600), optional MirrorView (CX600). No PowerPath, Utility Kit PowerPath, ATF, or CDE. No non-disruptive software installation (NDU). Clusters optional - Microsoft Cluster Server. Access Logix, optional SnapView, optional MirrorView (CX600). 18 on page 114 19 on page 115 Document Rev 19 Page 86 EMC Confidential

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149

February 3, 2003
EMC CLARiiON Open Systems Configuration Guide
Document Rev
19
Page 86
EMC Confidential
Windows NT Direct Connections
See
General Configuration Rules
(page 6).
Servers:
1 to 4 depending on configuration.
See
Paths from a Server to an SP (
page 10
)
,
Clustered Server Configuration Rules
(page 14),
Failover Configuration Rules
(page 15).
Storage Systems:
1 CX200, CX400, CX600, FC4500, FC4700, FC5300, or FC5700.
For the failover software supported for a storage system, see
Failover Configuration Rules
(page 15).
Configurations:
Storage
Systems
Servers
HBA Ports
per Server
Ports Used
per SP
Requirements/Comments
Diagrams
CX200
CX400
CX600
FC4500
FC4700
FC5300
FC5700
1
1
1
No PowerPath, Utility Kit PowerPath, ATF, or CDE.
No non-disruptive software installation (NDU).
Clusters not applicable.
No Access Logix, no SnapView, no MirrorView.
None
2
1
PowerPath or ATF.
Clusters not applicable.
No Access Logix, no SnapView, no MirrorView.
15 on page 111
CX400
CX600
FC4700
1
Multiple
Multiple
PowerPath or ATF.
Clusters not applicable.
No Access Logix, no SnapView, no MirrorView.
16 on page 112
CX200
CX400
CX600
FC4500
FC4700
FC5300
FC5700
2
1
1
No PowerPath, Utility Kit PowerPath, ATF, or CDE.
No non-disruptive software installation (NDU).
Clusters not supported.
No Access Logix, no SnapView, no MirrorView.
17 on page 113
CX200
CX400
CX600
FC4500
FC4700
FC5300
2
2
2
PowerPath or ATF.
Clusters required for storage system without Access
Logix; optional for storage system with Access Logix -
Microsoft Cluster Server.
No Access Logix (CX200, FC4500, FC5300),
optional Access Logix (CX400, CX600, FC4700),
optional SnapView (CX400, CX600, FC47600),
optional MirrorView (CX600).
18 on page 114
CX400
CX600
FC4700
Multiple
1
Multiple
No PowerPath, Utility Kit PowerPath, ATF, or CDE.
No non-disruptive software installation (NDU).
Clusters optional - Microsoft Cluster Server.
Access Logix, optional SnapView, optional MirrorView
(CX600).
19 on page 115