EMC CX600 Configuration Guide - Page 95

Single Fabric - QuickLoop and Fabric/Multiple HBA Ports /Multiple Ports per SP CX400, CX600, FC4700

Page 95 highlights

February 3, 2003 EMC CLARiiON Open Systems Configuration Guide 6. Single Fabric - QuickLoop and Fabric/Multiple HBA Ports /Multiple Ports per SP (CX400, CX600, FC4700) HP-UX H H B B A A NT H H B B A A FC Switch FC Switch NOTE: See General Configuration Rules (page 6), Failover Configuration Rules (page 15), and Switch Topology Rules (page 20). HP-UX Server Storage Group NT Server Storage Group 01 SP A 01 SP B LUN LUN LUN LUN LUN LUN LUN CX400 or FC4700 HP-UX Server Storage Group NT Server Storage Group 0123 SP A 0123 SP B LUN LUN LUN LUN LUN LUN LUN CX600 Legend = QuickLoop - SP port 0 = Fabric - SP Port 1 Benefits Hardware Server Operating Systems Other Server Software Clusters Storage Systems Storage-System Software Highly-available, QuickLoop and fabric switch connect to CX600 and FC4700 storage systems. HP-UX (QuickLoop or fabric) servers and non-HP-UX servers (fabric) with single or multiple HBAs. SP port 0 for QuickLoop; SP port 1 for fabric. 1 fabric. AIX, HP-UX, IRIX, Linux, NetWare, Solaris, Tru64 UNIX, Windows 2000, and Windows NT. PowerPath or Utility Kit PowerPath for AIX, Linux without clustering, NetWare, Solaris, Windows 2000, and Windows NT. PowerPath Base for Linux without clustering, NetWare, and Windows 2000. DMP for Solaris. ATF or CDE for AIX, NetWare, Solaris, Windows 2000, and Windows NT. PVLinks for HP-UX. Native failover for IRIX and Tru64 UNIX. No SP failover or non-disruptive software installation (NDU) for Linux with clustering. Optional multiple/alternate paths to each SP for AIX, Linux without clustering, NetWare, Solaris, Windows 2000, and Windows NT with PowerPath, for Solaris with DMP, for Windows 2000 and Windows with ATF and without clusters, and for non-clustered, multiple-HBA HP-UX, IRIX, and Tru64 UNIX servers. Optional: AIX (HACMP, HACMP/ES) HP-UX (MC/ServiceGuard) IRIX (FailSafe) Linux (Oracle9iRAC) NetWare (NetWare Cluster Service) Solaris (SunCluster only if not using DMP, Veritas Cluster Server) Tru64 UNIX (TruCluster) Windows 2000 (Microsoft Cluster Server or Oracle9iRAC) Windows NT (Microsoft Cluster Server). CX400, CX600, and FC4700. Access Logix; optional SnapView, optional MirrorView. Document Rev 19 Page 95 EMC Confidential

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149

February 3, 2003
EMC CLARiiON Open Systems Configuration Guide
Document Rev
19
Page 95
EMC Confidential
6.
Single Fabric - QuickLoop and Fabric/Multiple HBA Ports /Multiple Ports per SP (CX400, CX600,
FC4700)
HP-UX
H
B
A
H
B
A
NT
H
B
A
H
B
A
HP-UX Server
Storage Group
NT Server
Storage Group
= QuickLoop - SP port 0
Legend
= Fabric - SP Port 1
FC Switch
FC Switch
LUN
LUN
LUN
LUN
LUN
LUN
LUN
CX400 or FC4700
SP A
0
1
SP B
0
1
LUN
LUN
LUN
LUN
LUN
LUN
LUN
CX600
SP A
0
1
3
2
SP B
0
1
3
2
HP-UX Server
Storage Group
NT Server
Storage Group
Benefits
Highly-available, QuickLoop and fabric switch connect to CX600 and FC4700 storage systems.
Hardware
HP-UX (QuickLoop or fabric) servers and non-HP-UX servers (fabric) with single or multiple HBAs. SP port 0 for QuickLoop;
SP port 1 for fabric.
1 fabric.
Server Operating Systems
AIX, HP-UX, IRIX, Linux, NetWare, Solaris, Tru64 UNIX, Windows 2000, and Windows NT.
Other Server Software
PowerPath or Utility Kit PowerPath for AIX, Linux
without clustering
, NetWare, Solaris, Windows 2000, and Windows NT.
PowerPath Base for Linux without clustering, NetWare, and Windows 2000.
DMP for Solaris.
ATF or CDE for AIX, NetWare, Solaris, Windows 2000, and Windows NT.
PVLinks for HP-UX.
Native failover for IRIX and Tru64 UNIX.
No SP failover or non-disruptive software installation (NDU)
for Linux with clustering.
Optional multiple/alternate paths to each SP for AIX, Linux without clustering, NetWare, Solaris, Windows 2000, and
Windows NT with PowerPath, for Solaris with DMP, for Windows 2000 and Windows with ATF and without clusters, and for
non-clustered, multiple-HBA HP-UX, IRIX, and Tru64 UNIX servers.
Clusters
Optional:
AIX (HACMP, HACMP/ES)
HP-UX (MC/ServiceGuard)
IRIX (FailSafe)
Linux (Oracle9iRAC)
NetWare (NetWare Cluster Service)
Solaris (SunCluster only if
not
using DMP, Veritas Cluster Server)
Tru64 UNIX (TruCluster)
Windows 2000 (Microsoft Cluster Server or Oracle9iRAC)
Windows NT (Microsoft Cluster Server).
Storage Systems
CX400, CX600, and FC4700.
Storage-System Software
Access Logix; optional SnapView, optional MirrorView.
NOTE:
See
General Configuration Rules
(page 6),
Failover Configuration Rules
(page 15)
,
and
Switch Topology Rules
(page 20).