EMC CX600 Configuration Guide - Page 65

Solaris Direct Remote Mirror with Fabric Server Connections, Solaris Direct Remote Mirror

Page 65 highlights

February 3, 2003 EMC CLARiiON Open Systems Configuration Guide Solaris Direct Remote Mirror with Fabric Server Connections See General Configuration Rules (page 6) and Switch Topology Rules (page 20). Servers: Multiple with same or different operating systems. See Fan-Out Rule (page 9), Paths from a Server to an SP (page 10), Clustered Server Configuration Rules (page 14), Failover Configuration Rules (page 15). Storage Systems: 2 CX400, CX600, or FC4700 for remote mirroring. 1 per site per mirror configuration. For the failover software supported for a storage system, see Failover Configuration Rules (page 15). Server Connection: 1 to 2 local and remote fabrics. See Storage Area Network (SAN) Configuration Rules (page 9) and General Switch Topology Rules (page 20). Mirror Connection: SP port 3 (CX600) or SP port 1 (CX400, FC4700) for dedicated point-to-point mirroring. Extenders required for over 500 meters. Configurations: Storage Systems CX400 CX600 FC4700 Servers Multiple per site HBAs Ports per Server PowerPath, DMP multiple ATF - 1 or 2 Utility Kit PowerPath, CDE - 1 Ports Used per SP MirrorView - 1 PowerPath, DMP multiple (CX600) or 1 (CX400, FC4700) Utility Kit PowerPath, ATF, CDE - 1 Requirements/Comments PowerPath, Utility Kit PowerPath, DMP, ATF, or CDE Clusters optional for multiple HBA-port servers SunCluster only if not using DMP, Veritas Cluster Server. Access Logix, MirrorView, optional SnapView. Diagrams 13 on page 108 Solaris Direct Remote Mirror with Direct Server Connections See General Configuration Rules (page 6). Servers: 1 per site. See Paths from a Server to an SP (page 10), Failover Configuration Rules (page 15). Storage Systems: 2 CX400, CX600, or FC4700 for remote mirroring. 1 per site per mirror configuration. For the failover software supported for a storage system, see Failover Configuration Rules (page 15). Server Connection: Direct Mirror Connection: SP port 3 (CX600) or SP port 1 (CX400, FC4700) for dedicated point-to-point mirroring. Extenders required for over 500 meters. Configurations: Storage Systems CX400 FC4700 Servers 1 per site HBAs Ports per Server PowerPath, DMP multiple ATF - 2 Ports Used per SP MirrorView - 1 PowerPath, DMP multiple (CX600) or 1 (CX400, FC4700) ATF - 1 Requirements/Comments PowerPath, DMP, or ATF. Clusters not applicable. Access Logix, MirrorView, optional SnapView. Diagrams 14 on page 110 Document Rev 19 Page 65 EMC Confidential

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149

February 3, 2003
EMC CLARiiON Open Systems Configuration Guide
Document Rev
19
Page 65
EMC Confidential
Solaris Direct Remote Mirror with Fabric Server Connections
See
General Configuration Rules
(page 6) and
Switch Topology Rules
(page 20).
Servers:
Multiple with same or different operating systems.
See
Fan-Out Rule
(page 9),
Paths from a Server to an SP (
page 10
)
,
Clustered Server Configuration Rules
(page 14),
Failover Configuration Rules
(page 15).
Storage Systems:
2 CX400, CX600, or FC4700 for remote mirroring.
1 per site per mirror configuration.
For the failover software supported for a storage system, see
Failover Configuration Rules
(page 15).
Server Connection:
1 to 2 local and remote fabrics.
See
Storage Area Network (SAN) Configuration Rules
(page 9) and
General Switch Topology Rules
(page 20).
Mirror Connection:
SP port 3 (CX600) or SP port 1 (CX400, FC4700) for dedicated point-to-point mirroring.
Extenders required for over 500 meters.
Configurations:
Solaris Direct Remote Mirror with Direct Server Connections
See
General Configuration Rules
(page 6).
Servers:
1 per site.
See
Paths from a Server to an SP
(page 10),
Failover Configuration Rules
(page 15)
.
Storage Systems:
2 CX400, CX600, or FC4700 for remote mirroring.
1 per site per mirror configuration.
For the failover software supported for a storage system, see
Failover Configuration Rules
(page 15).
Server Connection:
Direct
Mirror Connection:
SP port 3 (CX600) or SP port 1 (CX400,
FC4700) for dedicated point-to-point mirroring.
Extenders required for over 500 meters.
Configurations:
Storage
Systems
Servers
HBAs Ports
per Server
Ports Used
per SP
Requirements/Comments
Diagrams
CX400
CX600
FC4700
Multiple
per site
PowerPath, DMP -
multiple
ATF - 1 or 2
Utility Kit PowerPath,
CDE - 1
MirrorView - 1
PowerPath, DMP -
multiple (CX600) or 1
(CX400, FC4700)
Utility Kit PowerPath,
ATF, CDE - 1
PowerPath, Utility Kit PowerPath, DMP, ATF, or CDE
Clusters optional for multiple HBA-port servers -
SunCluster only if
not
using DMP, Veritas Cluster
Server.
Access Logix, MirrorView, optional SnapView.
13 on page 108
Storage
Systems
Servers
HBAs Ports
per Server
Ports Used
per SP
Requirements/Comments
Diagrams
CX400
FC4700
1 per site
PowerPath, DMP -
multiple
ATF - 2
MirrorView - 1
PowerPath, DMP -
multiple (CX600) or 1
(CX400, FC4700)
ATF - 1
PowerPath,
DMP,
or A
TF.
Clusters not applicable.
Access Logix, MirrorView, optional SnapView.