Hayward E-Command 4 Model: ALL MODELS Installation

Hayward E-Command 4 Manual

Hayward E-Command 4 manual table of contents:

  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 1
    Hayward ECOMMAND 4 Automation Installation Manual for models HPC-4 HPC-4-ACT HPC-4-RC HPC-4-ACT-RC www.haywardnet.com
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 2
    ... the following READ AND FOLLOW ALL INSTRUCTIONS ! WARNING: Disconnect all AC power ... to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in ... conductors not smaller than 8 AWG US / 6 AWG Canada. • • • • SAVE THESE INSTRUCTIONS
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 3
    ...Introduction Before You Begin...1 Installation Steps...1 1. Mounting Equipment ECOMMAND 4 Control Center...Temperature Sensors...Optional Wireless Remote ... Voltage Pool Equipment...Low Voltage Wiring... 5 5 6 6 6 7 8 4. Configuration 5. System Startup and Checkout Configuration Menu...14 Before ...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 4
    ... You Begin What's Included Before attempting to install the ECOMMAND 4 system, check that the following components have been ...-RF/AQL2-SS-RF remote control (HPC-4-RC, HPC-4-ACT-RC only) ... hardware (screws, etc.) for mounting ECOMMAND 4 Valves (use standard Hayward, Pentair/Compool, or Jandy valves)...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 5
    ... facing downward. Because the enclosure also acts as a heat sink (disperses heat from inside ...RC, HPC-4ACT-RC) The ECOMMAND 4 is compatible with AQL2-SS-RF wireless remote control ... the "Teach Wireless" routine in the Settings Menu. This information can be found in the ECOMMAND 4 Operation Manual....
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 6
    ... station, remove the knockout on the upper left side of the ECOMMAND 4 main control unit, insert the base station, and then ... Base Station manual and the diagram on page 13. Optional Valve Actuators (included with HPC-4-ACT, HPC-4-ACT-RC) For optional actuators used with the ECOMMAND 4-note that ...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 7
    ... SOURCE SOLAR TEMPERATURE SENSOR SOLAR BOOST PUMP MANUAL VALVE CHECK VALVE FILTER SOLAR VALVE CHECK ... is used CELL FLOW SWITCH FILTER PUMP MANUAL VALVE POOL VACUUM VALVE TWO-WAY VALVE ... FEATURE Some important notes regarding the ECOMMAND 4 control of Standard Pool/Spa systems: In Pool/Spa Config., ...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 8
    ...applicable) codes -Use copper conductors only Main Service (Power to the Circuit Breaker Subpanel)...ECOMMAND 4 circuit breaker subpanel is rated for 100A service. Run properly rated conductors (L1... 4 control relays or circuit breakers. The ECOMMAND 4 should also be connected to the pool bonding system...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 9
    ...(supplied by installer) may be installed in the knockouts on the lower right side of the ECOMMAND 4 enclosure. Per code, the receptacle should be a GFCI type. Alternatively, connect a standard receptacle to a GFCB. ECOMMAND 4 Control Power The ECOMMAND 4 requires 120VAC, 2A power to operate ...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 10
    ... underneath the cover. ! WARNING: Do not use the ECOMMAND 4 to control an automatic pool cover. Two ... diagram below AND to configure the control logic according to the instructions on page 14. Lo ... lights will require an external transformer. For lighting systems that have both a light source and ...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 11
    ... 4 is compatible with standard valve actuators manufactured by Hayward, Pentair/ Compool, and Jandy. See ... on page 5 for the location of valve connectors. Heater Control The ECOMMAND 4 provides a set of low voltage ... voltage heaters, contact Goldline Tech support, 908-355-7995. Refer to the diagrams ...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 12
    ...heater to 120/240V power source per the instructions in the heater manual. The ECOMMAND 4 does NOT control the power going to the heater. 2. Wire the ECOMMAND 4 dry contact heater output per the diagram below. Many internal parts of the heater can get very hot--see the heater manufacturerମ.
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 13
    Hayward Heaters Refer to the instructions in the heater manual for "2-wire Remote Thermostat" operation under "Remote Control Connections" and ...Spa" (it doesn't make any difference which is selected, the ECOMMAND 4 will take control). 7. Heater display should be "bO" (for "bypass On...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 14
    ...on the board. ! IMPORTANT: The heater will display "OFF" when it is being remotely controlled by the ECOMMAND 4. Some homeowners see the "OFF" display and...the control box. Remove the jumper for the "fireman's switch. Wire to the ECOMMAND 4 using wire rated for 105°C minimum. Fireman's...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 15
    ... wiring between the ECOMMAND 4 and the Hayward Tristar Variable Speed Control (VSC). Connect ... Pump Owner's Manual (IS3220VSC) and Hayward document IS3220VSCAQLL for specific instructions on setting ... a solar heating system, the solar sensor is required. The sensors are provided with a 15 ft. cable....
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 16
    ...wireless" connector on the main PCB in the ECOMMAND 4 control unit. Connector for Base Receiver AQL2-BASE-RF Base Receiver Main PCB Tighten nut Goldline Aqua Rite or Hayward Swimpure Chlorinator The ECOMMAND 4 can control one or more Goldline Aqua Rite or Hayward...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 17
    ...requires the use of a Goldline Aqua Rite or Hayward Swimpure chlorinator), the ECOMMAND 4 will automatically chlorinate both... setting (see Settings Menu in the Operation manual). If disabled (default), all displays... detect and control any Aqua Rite/Swimpure(s) that is installed in the system (see page...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 18
    ... next menu item Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15..., (default ... you manually switch the Pool/Spa valves to "Spa Only", until the ECOMMAND 4 automatically ... previous positions. It is programmed in increments of 5 minutes, from "Manual On/Off" (0 minutes) to "21:00" (21 ...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 19
    If "Pool Only" is selected, then the ECOMMAND 4 will switch the pool/spa valves to the "pool ... 2speed and variable speed pump operation. For the Hayward Tristar variable speed pump: The Filter ..., the relay will be off. On , off and speed is controlled by commands sent to the pump. Lowest Speed ...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 20
    ...AIR temperature sensor falls below the freeze threshold (see below), the ECOMMAND 4 will turn on the filter pump to circulate the water. If "Pool ... heater cools down before water circulation is stopped. When enabled, the ECOMMAND 4 will continue to run the filter pump for 5 minutes after the heater...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 21
    ...Filter" is not selected Allow Low Speed Disabled Solar If the solar control logic is "Enabled", several additional steps must be taken to ensure proper operation of the solar system. If the solar is operated by a valve, then the Valve3 output must be ...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 22
    ... lights are used, the lights relay can be used to control other pool devices that may require ... LIGHTS button is pressed. There is no automatic control logic. Countdown Timer-the lights relay ... off. Low Speed of a 2-speed Filter Pump - the ECOMMAND 4 will turn on the lights relay whenever the low ...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 23
    .... When "Dimmer" is selected, and the Lights output is manually turned on, the "+" and "-" buttons adjust the level.../next configuration menu Rotates between Manual On/Off (default), Countdown Timer, Low... Menu ! WARNING: Do not use the ECOMMAND 4 to control an automatic pool cover. Swimmers...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 24
    ... aux button is pressed. There is no automatic control logic. Countdown Timer - the aux relay ...programmed time (see Timers Menu, Operation Manual). The AUX button can also be used ...falls below the selected freeze temperature threshold, the ECOMMAND 4 will turn on the aux relay to circulate the water....
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 25
    ... set for the valve3 timeclock in the Timers Menu (see Operations Manual). Solar - the valve operates when the filter pump is running and ... falls sensor falls below the selected freeze temperature threshold, the ECOMMAND 4 will turn on the valve to allow circulation of the water. IMPORTANT: this ...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 26
    ...previous/next configuration menu This selection affects ALL of the timeclock logic in the ECOMMAND 4. If "7-day" is selected, each timeclock will have one ...previous/next configuration menu Use this function to erase all previous system configuration and reset all configuration parameters back to...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 27
    ... Automatic Operation Refer to the programming flow chart on the back cover of this manual for a listing of the available menus and the items included in each... timer settings Heater Checkout Follow these instructions to verify that the ECOMMAND 4 is properly controlling the heater. 1. Check that the ...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 28
    ... detailed instructions on control and operation of the ECOMMAND 4 system, refer to the Operation Manual. Service ... the water temperature exceeds 104ºF (40ºC). Pushing the SERVICE button again will enter a timed... automatically return to normal operation. Push the SERVICE button once more to exit out...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 29
    26
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 30
    27
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 31
    ...Pro, Aqua Logic, Pro Logic and E-Command products to be free of defects in materials and ... centers please contact the Hayward/Goldline Technical Service Support Center ( 61 Whitecap ...used in or immediately adjacent to a pool or spa, war or acts of God. 4. 5. DISCLAIMER. THE EXPRESS LIMITED WARRANTY...
  • Hayward E-Command 4 | Model: ALL MODELS Installation - Page 32
    ECOMMAND 4 Programming Flow Chart default menu day and time water temperature air temperature... (not scheduled) countdown time remaining heater control status system manual off check system ... software revision filter bridge/vsc software revision RF base software revision configuration menu chlorinator ...