HP 100B Maintenance & Service Guide HP 100B All-in-One - Page 94
Control panel message, Description, Recommended action, Advanced, Bus Options, SERR# Generation - all in one ram
View all HP 100B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 94 highlights
Table A-1 Numeric Codes and Text Messages (continued) Control panel message Description Network Server Mode Active and No Keyboard Attached Keyboard failure while Network Server Mode enabled. Parity Check 2 Parity RAM failure or a PCI/PCIe device is asserting a SERR#. Recommended action 1. Reconnect keyboard with computer turned off. 2. Check connector for bent or missing pins. 3. Ensure that none of the keys are depressed. 4. Replace keyboard. Run Computer Setup and Diagnostic utilities. To disable a PCI/PCIe device from asserting a SERR#, run the Computer Setup utility and select Advanced > Bus Options > SERR# Generation > Disable. 86 Appendix A POST Error Messages
Table A-1
Numeric Codes and Text Messages (continued)
Control panel message
Description
Recommended action
Network Server Mode Active and No
Keyboard Attached
Keyboard failure while Network Server
Mode enabled.
1.
Reconnect keyboard with computer
turned off.
2.
Check connector for bent or missing
pins.
3.
Ensure that none of the keys are
depressed.
4.
Replace keyboard.
Parity Check 2
Parity RAM failure or a PCI/PCIe device is
asserting a SERR#.
Run Computer Setup and Diagnostic utilities.
To disable a PCI/PCIe device from asserting
a SERR#, run the Computer Setup utility and
select
Advanced
>
Bus Options
>
SERR# Generation
>
Disable
.
86
Appendix A
POST Error Messages