HP 8/8 Brocade Access Gateway Administrator's Guide v6.3.0 (53-1001345-01, Jul - Page 78

TABLE 10, connected to an M-EOS switch

Page 78 highlights

A Troubleshooting TABLE 10 Problem Troubleshooting (Continued) Cause Failover is not working Failover disabled on N_Port. Access Gateway is mode Access Gateway must be disabled. not wanted Solution Verify that the failover and failback policies are enabled, as follows: Enter the ag --failoverShow command with the port_number operand. Enter the ag --failbackShow command with the port_number operand. Command returns "Failback (or Failover) on N_Port port_number is supported." If it returns, "Failback (or Failover) on N_Port port_number is not supported." See "Adding a preferred secondary N_Port" on page 34. Disable switch using the switchDisable command. Disable Access Gateway mode using the ag --modeDisable command. Answer yes when prompted; the switch reboots. Log in to the switch. Display the switch settings using the switchShow command. Verify that the field switchMode displays Fabric OS Native mode. NOTE If a Fabric OS switch is in AG mode and is also set to McDATA Fabric mode, when that switch is connected to an M-EOS switch, the Fabric OS switch does not display in the output when you run the agshow command. 58 Access Gateway Administrator's Guide 53-1001345-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

58
Access Gateway Administrator’s Guide
53-1001345-01
Troubleshooting
A
NOTE
If a Fabric OS switch is in AG mode and is also set to McDATA Fabric mode, when that switch is
connected to an M-EOS switch, the Fabric OS switch does not display in the output when you run the
agshow
command.
Failover is not working
Failover disabled on N_Port.
Verify that the failover and failback policies are enabled, as follows:
Enter the
ag
--
failoverShow
command with the
port_number
operand.
Enter the
ag
--
failbackShow
command with the
port_number
operand.
Command returns “Failback (or Failover) on N_Port
port_number
is
supported.”
If it returns, “Failback (or Failover) on N_Port
port_number
is not
supported.” See
“Adding a preferred secondary N_Port”
on page 34.
Access Gateway is mode
not wanted
Access Gateway must be disabled.
Disable switch using the
switchDisable
command.
Disable Access Gateway mode using
the
ag
--
modeDisable
command.
Answer yes when prompted; the switch reboots.
Log in to the switch.
Display the switch settings using the
switchShow
command. Verify
that the field
switchMode
displays Fabric OS Native mode.
TABLE 10
Troubleshooting
(Continued)
Problem
Cause
Solution