HP ElitePad Mobile POS G2 Maintenance and Service Guide - Page 77

Bar code scanner module and Cable connector board, Detach the cable connector board cable

Page 77 highlights

9. Remove the front cover by sliding it away from the Retail Jacket. Reverse this procedure to install the front cover. Bar code scanner module and Cable connector board NOTE: The bar code scanner module and cable connector board spare part kits do not include the respective cables. The cables are included in the Cable Kit, spare part number 744031-001. Description Bar code scanner module Cable connector board Spare part number 744037-001 744034-001 Before removing the bar code scanner module and cable connector board, follow these steps: 1. Turn off the tablet. If you are unsure whether the tablet is off or in Hibernation, turn the tablet on, and then shut it down through the operating system. 2. Disconnect the power from the tablet by unplugging the power cord from the tablet or the Retail Jacket. 3. Disconnect all external devices from the Retail Jacket. 4. Remove the top cap (see Top cap on page 63). 5. If installed, remove the tablet from the Retail Jacket (see Top cap on page 63). 6. Remove the front cover (see Front cover on page 65). Remove the bar code scanner module and cable connector board: 1. Turn the front cover upside down with the top toward you. 2. Release the ZIF connector (1) to which the cable connector board cable is attached, and then disconnect the cable connector board cable from the system board. 3. Detach the cable connector board cable (2) from the front cover. (The cable connector board cable is attached to the front cover with double-sided adhesive.) 4. Remove the two Phillips PM1.3×3.0 screws (3) that secure the bar code scanner module to the front cover. 5. Remove the two Phillips PM1.9×3.0 screws (4) that secure the cable connector board to the front cover. Retail Jacket component replacement procedures 69

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126

9.
Remove the front cover by sliding it away from the Retail Jacket.
Reverse this procedure to install the front cover.
Bar code scanner module and Cable connector board
NOTE:
The bar code scanner module and cable connector board spare part kits do not include the
respective cables. The cables are included in the Cable Kit, spare part number 744031-001.
Description
Spare part number
Bar code scanner module
744037-001
Cable connector board
744034-001
Before removing the bar code scanner module and cable connector board, follow these steps:
1.
Turn off the tablet. If you are unsure whether the tablet is off or in Hibernation, turn the tablet on, and
then shut it down through the operating system.
2.
Disconnect the power from the tablet by unplugging the power cord from the tablet or the Retail Jacket.
3.
Disconnect all external devices from the Retail Jacket.
4.
Remove the top cap (see
Top cap
on page
63
).
5.
If installed, remove the tablet from the Retail Jacket (see
Top cap
on page
63
).
6.
Remove the front cover (see
Front cover
on page
65
).
Remove the bar code scanner module and cable connector board:
1.
Turn the front cover upside down with the top toward you.
2.
Release the ZIF connector
(1)
to which the cable connector board cable is attached, and then disconnect
the cable connector board cable from the system board.
3.
Detach the cable connector board cable
(2)
from the front cover. (The cable connector board cable is
attached to the front cover with double-sided adhesive.)
4.
Remove the two Phillips PM1.3×3.0 screws
(3)
that secure the bar code scanner module to the front
cover.
5.
Remove the two Phillips PM1.9×3.0 screws
(4)
that secure the cable connector board to the front cover.
Retail Jacket component replacement procedures
69